Tube/Cap Information
HSV (Cap Color)
When HSV is enabled, cap color values will be output in the following format:
(H)ue-(S)aturation-(V)alue
Example: 310-450-325
Notes:
This value is not output in read rate.
This value is not required to match when requiring more than one tube/cap to qualify for
an output.
Match Status (EZ Match Color Only)
Tube Diameter
Definition This feature is only available for the color version of the EZ Match Imager.
Match Status is output in the following format:
Format: cxxx.dxxx where “c” = cap color library match;
“d” = cap dimensions library match;
“xxx” = tube/cap library index
(When “xxx” = “000”, no match has occurred.)
While the cap library output mode will output the “best” match, the value
output from this mode will offer the last matched cap library index for color
and dimension. If both a color and dimension match has occurred, the last
cap library index that both color and dimension matched will be output.
Notes:
This value is not output in read rate.
This value is not required to match when requiring more than one tube/cap
to qualify for an output.
Serial Cmd: <K850,separator,tube/cap library index,tube angle
,tube/cap tip position,cap
color,
match status
,tube diameter
>
Default: Disabled
Options: 0 = Disabled
1 = Enabled
Definition When Tube Diameter is enabled, a four-digit value will be appended to
tube/cap detection output as a preamble.
This value represents the diameter of the tube in millimeters x10.
Example: 0835 represents 83.5 mm.
Serial Cmd: <K850,separator,tube/cap library index,tube angle
,tube/cap tip position,cap
color,match status,
tube diameter
>
Default: Disabled
Options: 0 = Disabled
1 = Enabled