User manual

7-12 HS-51/HS-51X Wireless Handheld Reader User Manual
Data Validation
ISO/IEC 15434
ISO/IEC 15434 specifies a transfer structure, syntax, and coding of messages and data
formats when using high capacity automatic data capture (ADC) technologies.
The following ISO/IEC 15434 data output options are applicable to Data Matrix ECC 200
symbols only and have no effect on other symbologies.
ISO/IEC 15434 Output Examples
ISO/IEC 15434 Enabled
(15434);05;0100061414199999;211A0B9C3D6;;;;;
(15434);06;7L0A1B3C;1P4202435;S10936;;;;
(15434);06;17V0A1B2;1P4202435;S10936;;;;
ISO/IEC 15434 Enabled with Error Messages
(15434);05;0100061414199999;211A0B9C3D6;;;;;
(15434);06;7L0A1B3C;1P4202435;S10936;;;;
(15434);06;17V0A1B2;1P4202435;S10936;;;;
(15434 ERROR: HEADER - 3RD POSITION);[)<DDCAG 12345SER
67890123▲♦;;;;;;;
(15434 ERROR: TRAILER - END OF TRANSMISSION);[)>12CAG 12345SER
67890123▲♣;;;;;;;
(15434 ERROR: HEADER - GROUP SEPARATOR);[)>12CAG 12345029SER
67890123▲♦;;;;;;;
Data Validation Disabled
The imager will return to normal output behavior without performing data validation.
ISO/IEC 15434
Enabled
Allows the imager to read only ISO/IEC 15434-compliant message
streams in Data Matrix ECC 200 symbols then output the ISO/IEC 15434
string. This implementation only checks the header/trailer format and
proper format indicator (00-99 and DD). The output string has a prefix, a
format indicator, and data components.
ISO/IEC 15434
Enabled with Error
Messages
Allows the imager to read only ISO/IEC 15434-compliant messages in
Data Matrix ECC 200 symbols and output detailed information such as
prefix, format indicator, data components, or error messages.
Data Validation
Disabled
Disables both UII and ISO/IEC 15434 data validation.