Specifications
Chapter 11  Utilities
MS-3 Laser Scanner User’s Manual 11-3
11–Utilities
Matchcode
<E> Enable Matchcode (see also <K223,...> on page 6-2.)
<F> Disable Matchcode (see also <K223,...> on page 6-2.)
<K224,number of 
master symbols>
Set master symbol database size. 
Also <KMnumber of master symbols>
<)data)> Enter symbol data as master symbol #1.
<K231,master sym-
bol number,data>
Enter symbol data to specified master symbol.
Also <Mmaster symbol number,data>
<G> Store next symbol scanned as master symbol #1.
<Gmaster symbol 
number>
Store next symbol scanned as specified master symbol.
<)> Request master symbol #1.
<K231,?>
Request all master symbol information.
Also <M?>
<K231,master sym-
bol number?>
Request specified master symbol information.
Also <M#?>
<K231,master sym-
bol number,>
Delete specified master symbol.
Also <Mmaster symbol number,>
<))> Delete Master Symbol # 1
<K225,status> Enable/disable New master pin
Network 
Status
<n> Network status Command
Status Requests
<?>  Scanner Status
<?1> Extended scanner status
<K?> Configuration status
Table 11-1 Summary of Utility Serial Commands