User`s manual
7-10 MS-4 Imager User’s Manual
2D Symbology Qualification
2D Symbology Qualification
Note: In the cases where Symbol Size Status, Dimension Status, or Orientation Status 
is enabled, the Imager will always check the finder pattern regardless of Finder Patter 
Status setting.
Finder Pattern Status
Symbol Size Mode (2D Symbology Qualification)
Note: If Symbol Size 1 is larger than Symbol Size 2, it will be automatically reversed in 
the algorithm.
Disabled
Decoded messages are output, but no attempt to qualify symbols or output Bad or No 
Symbol messages is undertaken.
Bad/No Symbol Output
Checks first for decodes. If no symbol is decoded, checks for symbol size. If both Symbol 
Size 1 and Symbol Size 2 requirements are met, a Bad Symbol message is output. If 
neither are met, a No Symbol message is output.
Object Qualification
Checks first for matches to symbol size. If qualified, attempts to decode. If no decodes are 
found within the specified read cycle parameters, outputs a No Read message.
Enable Both
Same as Object Qualification, except that if no objects qualify, then a No Symbol message 
is output; if at least one object qualifies, then a Bad Symbol message is output.
Definition: Checks for the presence of a finder pattern.
Serial Cmd: <K718,finder pattern status,symbol size mode,symbol size 1,symbol 
size 2,symbol size tolerance,dimension mode,dimension 1,dimension 
2,dimension tolerance,orientation mode,orientation value>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Specifies the outputs resulting from the searches for Symbol Size 1 and 
Symbol Size 2.
Serial Cmd: <K718,finder pattern status,symbol size mode,symbol size 1,symbol 
size 2,symbol size tolerance,dimension mode,dimension 1,dimension 
2,dimension tolerance,orientation mode,orientation value>
Default: Disabled
Options: 0 = Disabled
3 = Enable Both
1 = Bad/No Symbol Output 2 = Object Qualification