MS-4 Imager User’s Manual 4-7
Calibration
Window of Interest Framing Disabled
When this feature is disabled, the Window of Interest is not modified after the calibration 
process is complete. 
Row and Column
If the calibration process is successful, the Window of Interest will be modified to frame the 
symbol as well as an additional margin area around the symbol, determined by the WOI 
Margin parameter. Refer to the diagram below:
Column
If the calibration process is successful, the Window of Interest columns will be modified to 
vertically frame the symbol, plus an additional margin area around the symbol, determined 
by the WOI Margin parameter. Refer to the diagram below:
Row
I
f the calibration process is successful, the Window of Interest rows will be modified to horizontally 
frame the symbol, plus an additional margin area around the symbol, determined by the 
WOI 
Margin
 parameter. Refer to the diagram below: