Specifications
Doc Number: VIS-ANA-VER-01001-9002
Date: 27 May 2004
Issue: 5.0
Page: 20 of 80
Author: J. Delgadillo
Controls Preliminary Design Report Issue 5.doc
TABLE 4.2.1 LVD & EMC Test Standards & Limits
STANDARD TITLE MCS LIMITS AD10 LIMITS
EN 50081,
Part 2
Electromagnetic Compatibility – Generic
Emission Standard
Part 2: Industrial Environment
(Class A)
CONDUCTED
0.15 – 0.5 MHz
QP 79, AVG 66 dBµV
0.5 – 30 MHz
QP 73, AVG 60 dBµV
RADIATED (@ 10 m)
30 – 230 MHz
39.5 dB(µV/m)
230 – 1000 MHz
46.5 dB(µV/m)
CONDUCTED
0.15 – 0.5 MHz
66-56 dBµV QP
0.5 – 5 MHz
56 dBµV QP
5 – 30 MHz
60 dBµV QP
RADIATED (10m)
30 – 230 MHz
30 dB(µV/m)
230 – 1000 MHz
37 dB(µV/m)
IEC 61000-4-2 Electromagnetic Compatibility – Part 4: Testing
and Measurement Techniques – Part 2:
Electrostatic Discharge (ESD) Immunity
LEVEL 2
4KV Contact Discharge
LEVEL 3
8KV Air Discharge
LEVEL 3
6KV Contact
Discharge
8KV Air Discharge
IEC 61000-4-3 Electromagnetic Compatibility – Part 4: Testing
and Measurement Techniques – Part 3: Radiated
Radio-Frequency, Electromagnetic Field
Immunity Test
LEVEL 2
80 to 1000 MHz
80% AM @ 1KHz
3 V/m
LEVEL 3
80 to 1000 MHz
80% AM @ 1KHz
10 V/m
IEC 61000-4-4 Electromagnetic Compatibility – Part 4: Testing
and Measurement Techniques – Part 4: Electrical
Fast Transient Immunity
LEVEL 2
0.5KV on I/O Signal and
Control Lines
1KV on PS Lines
LEVEL 2
0.5KV on I/O Signal
and Control Lines
1KV on PS Lines
IEC 61000-4-5 Electromagnetic Compatibility – Part 4: Testing
and Measurement Techniques – Part 5: Surge
Immunity
CLASS 2
Line to Earth 1KV
Line to Line 0.5 KV
CLASS 3
Line to Earth 2KV
Line to Line 1 KV
IEC 61000-4-6 Electromagnetic Compatibility – Part 4: Testing
and Measurement Techniques – Part 6: Immunity
to Conducted Disturbances, Induced by Radio-
Frequency Fields
LEVEL 2
150 KHz to 80 MHz
3 Vrms 80% Mod.
Not Specified
IEC 61000-4-11
Electromagnetic Compatibility – Part 4: Testing
and Measurement Techniques – Part 11:
Immunity Requirement, Voltage Dips, Short
Interruption and Voltage Variation
30% reduction (10ms)
60% reduction (100 ms)
>95% reduction (5 sec)
30% reduction,10ms
50% reduction,0.1s
>95% reduction,5sec
EN 61000-3-2 Electromagnetic Compatibility Part 3: Limits-
Section 2: Limits for Harmonic Currents
Emissions (Equipment Input Current <=
16A/phase)
Class A Limits
Refer to Standard
Not Specified
EN 61000-3-3 Electromagnetic Compatibility Part 3: Limits-
Section 3: Limitation of Voltage Fluctuations and
Flicker in Low Voltage Supply Systems for
Equipment with Rated Current <= 16A
Class A Limits
Refer to Standard
Not Specifie d