Specifications
Doc Number: VIS-ANA-VER-01001-9002
Date: 27 May 2004
Issue: 5.0
Page: 78 of 80
Author: J. Delgadillo
Controls Preliminary Design Report Issue 5.doc
15 AZ-ALT Regen Overtemp Fault DCC. Contacts Open = Fault (SF)
16 AZ Motor #1/#2 Emergency Stop DCC. Contacts Open = Emergency
Condition (I) (SF)
17 AZ Motor #3/#4 Emergency Stop DCC. Contacts Open = Emergency
Condition (I) (SF)
18 ALT Motor #1 Emergency Stop DCC. Contacts Open = Emergency
Condition (I) (SF)
19 ALT Motor #2 Emergency Stop DCC. Contacts Open = Emergency
Condition (I) (SF)
20 ALT Pier Emergency Stop DCC. Contacts Open = Emergency
Condition (I) (SF)
21 Equipment Room Emergency Stop DCC. Contacts Open = Emergency
Condition (I) (SF)
22 Cone Emergency Stop DCC. Contacts Open = Emergency
Condition (I) (SF)
23 ALT Brake Manually Released DCC. Contacts Open = ALT Brakes
Manually Released
24 M2 Unit Not Installed DCC. Contacts Open = Not Installed (I)
(SF)
25 CASS Instrument Not Installed DCC. Contacts Open = Not Installed (I)
(SF)
26 DSP Boot Failure DCC. Contacts Open = DSP Failure (SF)
27 ALT Imbalance Pin Cradle DCC. Contacts Open = Not in Cradle
28 OSS Not installed DCC. Contacts Open = OSS Not
Installed (I) (SF)
29 M1 Mirror Restraint Failure DCC. Contacts Open = M1 Restraint
Failure (I) (SF)
30 AZ Floor Access Interlock DCC. Contacts Open = Access INLTK
(I) (SF)
31 Mobile Access Platform Interlock DCC. Contacts Open = Access INLTK
(I) (SF)
32 Common Isolated Return for above contacts
DCC – Dry-Contact Closure
(I) – Causes Interlock
(SF) – Causes Summary Fault