User's Manual

Page 36
NewStream User Guide and Technical Manual
Figure 21: NewStream CNG Information Touchscreen
CNG Touchscreens
When the NewStream has the capability of operating in a cellular mode, the
touchscreens are labeled CNG displaying information and settings speci c to cellular
transmission. When the
NewStream does not detect the cellular ODU, the CNG
information screen shows the message Cellular ODU is loading, please wait. Once
the cellular ODU has booted up and can provide information about its con guration, the
message changes to a status screen describing the current connectivity of the modems
in the cellular ODU. This CNG Information screen displays the following:
1. A graphical representation of the current RSSI per modem using signal strength
bars similar to a phone.
a. If RSSI > 120 = 5 gray bars
b. If RSSI > 95 and < 120 = 1 red bar, 4 gray bars
c. If RSSI > 85 and < 95 = 2 amber bars, 3 gray bars
d. If RSSI > 75 and < 85 = 3 amber bars, 2 gray bars
e. If RSSI > 60 and < 75 = 4 green bars, 1 gray bar
f. If RSSI > 1 and < 60 = 5 green bars
g. When a modem is not detected the words No Modem replace the signal bars
graphic.
h. If a modem is detected but there is no SIM card installed, the words No Card
replaces the signal bars.
i. If a modem and a SIM card are detected but not yet not connected to a
network, the word Connecting replaces the signal bars
2. The name of the carrier to which the modem is connected.
3. The service [3G/4G/LTE] to which the modem is connected.
4. The number of the SIM card slot in which the SIM is inserted.
The CNG Information touchscreen is shown below in Figure 21. This screen displays
the relative signal strength information for each of the six modems