User Manual Part 1

Troubleshooting 4-2MTX5000 User and Technical Manual
Figure 4-4: Summary Alarm Dialog Box - Typical
In all cases, the error message will uniquely identify the problem,
i.e., +5.5V Powersupply Error.
To isolate possible IDU problems, see “Perform IDU Diagnostics”
on page 3-56.
See Table 4-1 for a list of Indoor Unit (IDU) error messages and
what to do when they appear.
Table 4-1: IDU Error Messages
Error Message Error Type
Suggested Technical
Staff Action
+5.5V Powersupply
Error
Major Indicates internal
power supply failure
and potential unstable
operation. Verify IDU
input power.
Call MRC Technical
Support.
+12V Powersupply
Error
OK
Summary Alarm
xxxxxxxxxxxxxxxxx
+24V Powersupply
Error
Minor Indicates minor
internal power supply
failure. Verify IDU
input power.
Call MRC Technical
Support.
-12V Powersupply Error
Ext IF Level Too High Minor Indicates external IF
level is above
recommended level.
Attenuate or
disconnect signal to
avoid system
damage.
Call MRC Technical
Support.
FMT Fault Alarm Major Indicates internal
hardware fault.
Call MRC Technical
Support.
Audio1 Unlocked Minor Verify audio input is
connected
Audio2 Unlocked
Audio3 Unlocked
Audio4 Unlocked
Analog Video Unlocked Minor Verify composite video
input is connected.
Table 4-1: IDU Error Messages
Error Message Error Type
Suggested Technical
Staff Action