User Manual Part 2

Installation 6-22MTX5000 User and Technical Manual
ANT CONTROL 7-pin Weidmuller connector The ANT CONTROL connector provides
control for antenna polarization, antenna
band selection, the RF switch, and also
provides DC power for the antenna and
the RF switch.
A 7-pin Weidmuller female connector
is provided for new system
applications. For retrofit applications,
the existing 5-pin and 2-pin
Weidmuller female connectors may be
retained. See Table 6-6 on page 6-22
for pinouts.
RFU 1 and RFU 2 •Triax
N or TNC (optional)
IF + DC Power + Control to RFU
IF + Control to RFU (optional)
Connector type depends on which
connector ordered. RFU 2 connector
present only if 2 band option ordered.
POWER IN AC - IEC 3 prong recessed male Supplies power to the MTX5000 system. 110 - 220 VAC, 50/60 Hz
Grounding Lug #8-32 threaded post Connection to chassis ground
Table 6-6: Antenna Control - Feed and Relay Connections
Pin (New
Applications)
Pin (Retrofit
Applications)
Function Description Comments
Antenna Control
11H Selects horizontal
polarization.
Connect pins 1, 2, or 3 to GND (pin 6 or 1 in Feed/Relay
Power below) to select desired polarization. If all are left
ungrounded, antenna defaults to right circular (RC)
polarization. Selecting Ant. Pol. option button options on color
LCD display panel causes each pin, in turn, to be grounded or
all to be ungrounded. When ungrounded, should have +24
volts DC returning from antenna.
22V Selects vertical
polarization.
33LCP Selects left circular
polarization.
Table 6-5: IDU Rear Panel Connections (Continued)
Connector Type Function Comments