User Manual Part 2

Installation 6-27MTX5000 User and Technical Manual
Figure 6-17: Mobile Operations Remote Control - Typical
The MTX5000 system may also be controlled using a Remote
Access Subnotebook or a Windows-based laptop PC from a
remote location. When controlling the MTX5000 system from a
remote location, the remote PC is connected to the MTX5000
system via the Ethernet. A standard RJ-45 cable is used when
connecting to the MTX5000 system via the Ethernet. A
crossover cable may not be used from a remote location for
connection to the Ethernet.
6.17 Powering Up
When the wiring and installations are completed, it is time to
power up the MTX5000 system. As good practice, you should
make a final check of all wiring and hardware installations before
power is applied.
ETHERNET
RTN DATA
WAYSIDE
ATP C
AUDIO
1
2
3
4
+ G -
+ G -
+ G -
+ G -
SUM
ALARM
AES/EBU
VIDEO IN
BB IN
S
+ G -
+ G -
1
2
ETHERNET Connector
RJ-45
Crossover
Cable
Optional Remote Access
Subnotebook PC or
Windows-Based Laptop
6.17.1 Checks Before Power-Up
CAUTION
Be sure the power being supplied matches
the power required by the equipment.
Here are your final pre-power-up checks:
Double check to verify all wiring harnesses and cables are
connected to the correct connectors.
Make sure all connections are fully mated, properly
mated, and are secured.
Verify an ODU is properly connected to the IDU.
Verify all assemblies are properly installed and all
mounting hardware is properly tightened.
6.17.2 Initial Power-Up
CAUTION
If power is accidentally lost or if the power
switch is pressed to off, do not immediately
power up the MTX5000 again.
Internal software corruption may occur if
power is applied immediately after a power
loss or if the power switch is pressed to off
and immediately back to on.
To avoid possible software corruption, wait a
minimum of 10 seconds before applying
power or before pressing the power switch
to on.