User Manual Part 2

A
Installing Triax Connectors A-1MTX5000 User and Technical Manual
Installing Triax Connectors
A.1 Appendix Overview
Installing Triax connectors on a Triax cable is an exacting job. If
not performed correctly, it can lead to intermittent or permanent
failures due to vibration, moisture, etc.
As a service to our customers, MRC is providing a copy of our
Triax Cable Assembly Instructions. We have found this
procedure to work well and the results to be reliable.
A.2 Sealing
For any outdoor application, such as mast top connections, we
recommend you seal all connections with self-fusing butyl rubber
or silicone tape. Ordinary plastic electrical tape and cloth
friction tape are not recommended.
A good general practice is as follows:
Connect and tighten the connector
Begin wrapping the tape tightly against the enclosure, and
wrap in a spiral back toward the cable
Overlap each turn with the next turn by about half its width
Continue wrapping and overlapping until the tape extends
at least 2 inches beyond the connector.
Self-fusing tape can be purchased from industrial supply
companies such as Grainger (www.grainger.com) and
McMaster-Carr (www.mcmaster.com). Self-fusing tape is also
available at larger hardware stores such as DoitBest.com
(www.doitbest.com).
COMMUNICATIONS
MICROWAVE RADIO