User Manual Part 2

Analog Color Bar Generator B-6MTX5000 User and Technical Manual
Figure B-3: Control Switch Locations
4. Connect an AC power cable to the MTX5000 IDU rear
panel AC POWER IN connector.
5. Connect the MTX5000 IDU power cable to AC power
of the correct type and voltage.
6. Verify the power source is turned on.
CAUTION
Exercise care to avoid damage to exposed
circuitry in the MTX5000 IDU.
When connecting test cables in the following
steps, do not allow the test cable BNC
connector and the BNC connector on the
cable connected to the external monitor to
come in contact with any circuit boards
contained in the MTX5000 IDU.
7. Connect the CBG test cable supplied with your
MTX5000 IDU to the CBG video monitor connector J4.
See Figure B-1 on page B-3.
8. Connect a BNC cable between an external monitor
and the CGB test cable BNC connector.
9. Verify the external monitor is powered up.
1
2
3
4
SW1
SW2
SW3
SW4
10. Raise the MTX5000 IDU power switch protective
cover, press the power switch, observe the symbol on
the power switch illuminates green, and close the
protective cover.
Notes
When power is applied to the MTX5000 IDU, it will
automatically enter the local mode of operation.
The MTX5000 will return to the last settings that
were in use when the unit was powered down, but
the unit will not resume transmitting if the unit was
transmitting when it was powered down.
11. The normal power-up sequence is as follows:
- After a short delay, the introduction screen will be
displayed on the color LCD display panel. See
Figure B-4. A progress bar will also be displayed
indicating power up progress.
- When the power up sequence is complete, the Main
screen will be displayed on the color LCD display
panel. See Figure B-5 on page B-7.
Figure B-4: Introduction Screen
Progress
Bar (Typical)