User Manual

Table Of Contents
Advanced Operation 5-7PTX-PRO User and Technical Manual
Figure 5-4: Create New Configuration On-Line - Sheet 3 of 5
Audio A and
Audio B
Input
Select Test
Tone, Analog,
SDI EMB, or AES
EBU (Active in
MPEG mode
only)
Mode
Select Stereo or
Dual Mono, as
required (Active
in MPEG mode
only)
Type
Select OFF or
MPEG, as
required
Encryption PID Info
AUD-A
Enter Audio A
PID, as required
(Range is 32 -
8190)
AUD-B
Enter Audio B
PID, as required
(Range is 32 -
8190)
DAT
Enter data PID,
as required
(Range is 32 -
8190)
Default PID
If check box is
selected, default
PIDs will be used.
If check box is
not selected, PID
data must be
entered manually
PCR
Enter PCR PID,
as required
(Range is 32 -
8190)
Spectrum
Polarity
VID
Enter video PID,
as required
(Range is 32 -
8190)
Wayside
Baud
Select 1200,
2400, 4800,
9600, 19200, or
38400, as
required (Active
in IRD
Compatible and
Strata
Compatible only)
State
Select Off, IRD
Compatible, or
Strata
Compatible, as
required
B
Note
Enter PIDs only if Default PID was not checked.
If Default PID was checked, go to COFDM tab.
Type
Select OFF,
BISS-1, or BISS-
E, as required
Select Normal or
Inverted, as
required (Not
active on some
radio
configurations)
E Key and E ID 1 Key
Enter 1 Key data
Enter E Key and
E ID data
Note
BISS encryption is a factory-enabled option.
BISS options may only be selected if BISS has
been enabled at the factory.
From
Figure