User Manual

Routine Operation 3-18STRATA TX Operator’s Guide/Tech Ref Manual
5. Connect the TCU or TXU to DC power of the correct
voltage and polarity.
If you are unsure of the power requirements or the
connections, refer to the Installation” Chapter on
page 6-1 chapter (Part of the STRATA TX System
Technical Reference Manual only).
If the TCU/TXU is powered from the optional STRATA
ACU, connect the ACU input to AC power and verify
the TCU/TXU power cable is connected to the ACU
DC OUTPUT connector. Set the ACU power switch to
I (on) and verify the ACU power LED is on.
If the TCU is powered from a source other than an
ACU, turn that power source on.
6. Set the TCU PWR switch to I (on).
7. The normal power-up sequence is as follows:
- The Status LED above the PWR switch should
illuminate and should change colors from red, to
green, to amber, and finally remain green.
- The alphanumeric display should light up and quickly
display a self-test screen, then the version of the
installed firmware, and finally the Main Screen.
Some typical screens are shown in Figure 3-14. The
exact screens will vary depending on installed
hardware.
- The TCU will typically power up using the last settings
in use when power was turned off.
- If the TCU does not power up normally, refer to the
“Troubleshooting” Chapter on page 4-1.
Figure 3-14: Typical TCU Power Up Screens - Separately
Located TXU and TCU
8. Rotate the TCU Control Switch ccw until the 75 Ohm
Coax
option (Figure 3-15) is displayed on the
alphanumeric display.
Figure 3-15: 75 Ohm Coax Option
9. Press Control Switch to change Power Off to read
Power On, as required.
10. Set the TXU PWR switch to I (on).
11. The normal power-up sequence is as follows:
- The Status LED above the PWR switch should
illuminate and should change colors from red, to
green, to amber, and finally remain green.
- The alphanumeric display should light up and quickly
display a self-test screen, then the version of the
STRATA TX
V 0.1.1
Preset 1
0.00W
Firmware
Version
Main Screen
75 Ohm Coax
Power Off