DL451 Modular I/O
Operator Manual
3 Press SELECT.
4 Press MENU.
5 To exit programming mode, press MENU. The default
display will now show the newly configured ID number
at the end of the bottom line.
5 Digital boards menu
This menu lets you set up the following for any digital I/O board(s) fitted in the unit:
Clock source — synchronise the digital outputs from the inputs or set them at 48k
or 96k.
Sample rate converter (SRC) — switch the SRC on/off for each input/output
channel pair. As this option is ‘intelligent’ it may be disabled, depending on the other
settings.
Word size — set up the word size for the digital outputs as 16, 20 or 24 bits.
This menu has three boards to choose from — A, B and C — representing the module
slot positions printed on the rear panel.
Note: If there are no digital I/O boards fitted, this menu does not appear.
>> To set up the clock source for the digital outputs
1 In programming mode, select menu 5 (see “To select a
menu” on page 9).
2 Press MENU.
3 Use the down arrow button to go to the board you
want to set up. For example, board “C”.
4 Press SELECT.