Operation Manual
Setting up the I/O rack devices 93
PRO Series Live Audio Systems
Owner’s Manual
To cater for the dual redundant ports of the DL431 Mic Splitter and DL451 Modular I/O
(X and Y connections) there are two options in the device type drop-down list,
MS Cable Red and Line Io Cable Red, respectively. Initially, the device is allocated
to a port (as for any device), then a second port is allocated to the redundant
connection, but with the same device ID (see below for details).
Device set-up procedure
The device set-up procedure comprises:
• Selecting the port (Stage or FOH) you wish to allocate the device to.
• Selecting the device type.
• Selecting an ID for the device.
• Selecting the options (if any) for the device.
>> To add a device or change its set up
1 Click CONFIG to open the AES50 Device Configuration window.
2 Click the port you want to allocate the device to. For example, “FOH Port 3
(unused)”. The text in the device type: field will change accordingly. (A port
that has no device allocated to it will have the text “(unused)” after its name.)
3 In the device type: drop-down list, click the type of device. For example,
“DL351A”.
4 In the device ID: drop-down list, click the ID you want for the device. For
example, “ID6”.
5 In the device options: drop-down list, click the type of card fitted physical unit.
For example, “Analogue 8 Input”. If there is more than one device options:
drop-down list, repeat for the remaining ones, making sure they match the actual
cards fitted.
6 Click CLOSE.
>> To remove a device
Select the port/device from the list in the left of the AES50 Device Configuration
window. Then, select “None-Unknown” in the device type: drop-down list. For further
details, see “To add a device or change its set up” on page 93.
3 device ID drop-down list, contains a full list of IDs for the selected device
type. Those already in use will be prefixed with the text “(In use)”.
4 device options drop-down list(s), from which you can select the card that
is actually fitted in the physical unit. The positions of the drop-down lists
are relative to the card positions in the physical unit.
5 CLOSE button, closes the AES50 Device Configuration window.
Item Description