Operation Manual

Setting up the I/O rack devices 93
PRO Series Live Audio Systems
Owner’s Manual
To cater for the dual redundant ports of the DL431 Mic Splitter and DL451 Modular I/O
(X and Y connections) there are two options in the device type drop-down list,
MS Cable Red and Line Io Cable Red, respectively. Initially, the device is allocated
to a port (as for any device), then a second port is allocated to the redundant
connection, but with the same device ID (see below for details).
Device set-up procedure
The device set-up procedure comprises:
Selecting the port (Stage or FOH) you wish to allocate the device to.
Selecting the device type.
Selecting an ID for the device.
Selecting the options (if any) for the device.
>> To add a device or change its set up
1 Click CONFIG to open the AES50 Device Configuration window.
2 Click the port you want to allocate the device to. For example, “FOH Port 3
(unused)”. The text in the device type: field will change accordingly. (A port
that has no device allocated to it will have the text “(unused)” after its name.)
3 In the device type: drop-down list, click the type of device. For example,
“DL351A”.
4 In the device ID: drop-down list, click the ID you want for the device. For
example, “ID6”.
5 In the device options: drop-down list, click the type of card fitted physical unit.
For example, “Analogue 8 Input”. If there is more than one device options:
drop-down list, repeat for the remaining ones, making sure they match the actual
cards fitted.
6 Click CLOSE.
>> To remove a device
Select the port/device from the list in the left of the AES50 Device Configuration
window. Then, select “None-Unknown” in the device type: drop-down list. For further
details, see “To add a device or change its set up” on page 93.
3 device ID drop-down list, contains a full list of IDs for the selected device
type. Those already in use will be prefixed with the text “(In use)”.
4 device options drop-down list(s), from which you can select the card that
is actually fitted in the physical unit. The positions of the drop-down lists
are relative to the card positions in the physical unit.
5 CLOSE button, closes the AES50 Device Configuration window.
Item Description