Operation Manual

Auxes (Aux Sends) 399
PRO2 Live Audio System
Owner’s Manual
EQ safe
The following diagram details the parameters in the auxes protected by the EQ safe,
and shows the EQ detail area in the GUI channel strip and the GEQ window on the GUI
screen.
* Not shown in diagram.
Note: Although bands 5 and 6 are not shown above, the items in the table also apply.
Both bands have items 2, 3 and 4, and band 6 also has item 7.
Item Control Parameter
1 EQ switch EQ on/off
2 gain control knob EQ gain level
3 width control knob EQ width
4 freq control knob EQ frequency
5 SHAPE switch Band 1 shelving mode: parametric, warm, high
pass 6dB or high pass 12dB
6 SHAPE switch Band 2 shelving mode: parametric or high pass
24dB
7* SHAPE switch Band 6 shelving mode: parametric, soft, low pass
6dB or low pass 12dB
4
2
3
4
2
3
6
2
3
5
2
3
4
1
4
1
4
5/6/7
2
3