Operation Manual

Troubleshooting automation 405
PRO Series Live Audio Systems
Owner’s Manual
not in storing
state
Automation The Automation System was
momentarily unable to store
a scene.
Try again. If repeated
attempts fail, contact Midas
Technical Support.
null pointer File and
Automation
Critical internal error. This is an indication of a
serious error. Contact Midas
Technical Support.
p
persistent storage
error
File and
Automation
The GUI or one of its
subsystems is out of date and
cannot interpret the new
failure modes.
Update the GUI and its
subsystems.
If the problem persists,
contact Midas Technical
Support.
point scene index
continuity error
File and
Automation
The show file being modified
is damaged.
This is an indication of a
serious error. Contact Midas
Technical Support.
point scene index
integrity error
File and
Automation
The show file being modified
is damaged.
This is an indication of a
serious error. Contact Midas
Technical Support.
point scene insert
error
File and
Automation
Failed to insert a point scene. This is highly unlikely to occur
in practice, but is an
indication of a serious error.
Contact Midas Technical
Support.
portable scene
format conversion
error
Automation The attempt to load a show,
which was last saved by an
MC built with a different
enum version, failed during
the scene conversion stage of
the loading process.
Try again. If repeated
attempts fail, contact Midas
Technical Support.
r
required device
has files that are
in use
File and
Automation
Another task is currently
accessing file(s) on the
device, that is, the internal
compact flash of the PRO
Series or USB memory stick
(if connected).
Try again.
required device is
locked
File and
Automation
Another task is currently
accessing the device, that is,
the internal compact flash of
the PRO Series or USB
memory stick (if connected).
Try again.
s
scene capacity
violation
File and
Automation
The scene cannot be stored
to the show file, as it already
contains the maximum
number of scenes allowed.
If necessary, delete one or
more of the other scenes.
The maximum capacity for a
show file is 500 scenes for a
512MB master controller
(MC) and 1000 scenes for a
1GB MC.
scene UID error File and
Automation
The file being modified is
damaged.
This is an indication of a
serious error. Contact Midas
Technical Support.
Error Message System(s) Problem Solution