Installation Instructions

55
66
2. Drill a hole in the wall
3. Connective pipe installation
Wall
Indoor
Outdoor
5-7mm
Fig.3
INDOOR UNIT INSTALLATION
1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete
or the like, drill five 5mm diameter
holes in the wall and insert Clip
anchor for appropriate mounting
screws.
3. Secure the installation plate to the
wall with screws.
1. Installation Plate Mounting
Remove the installation plate from
the indoor unit.The installation plate
should be installed on a wall which can
support the weight of the indoor unit.
Right rear side
refrigerant pipe
hole 65
Right rear side
refrigerant pipe
hole 65
Right rear side
refrigerant pipe
hole 65
Left rear side
refrigerant
pipe hole 65
Left rear side
refrigerant
pipe hole 65
Left rear side
refrigerant
pipe hole 65
Indoor unit
outline
Indoor unit
outline
Indoor unit
outline
Model B
Model A
Model C
Model D
182
209
172
581
242
53.5
138
29
43
59
12
34
40
144
98
76
810
980
730
128
184
300
325
293
43
51
6.6
14
6.6
14
38.5
43
51
101
136
INDOOR UNIT INSTALLATION
INDOOR UNIT INSTALLAITON
Fig.2
1. Determine hole positions according to left
and right side of the installation plate. The hole
center is obtained by measuring the distance as
shown in the diagram of Fig.2.
2. Dirll the piping plate hole with 65mm hole-core drill.
3. Drill the piping hole at either the right or the left and
the hole should be slightly slanted to the outdoor side,
so that the outside end is lower than inside end,see Fig.3.
4. Always take steps to protect the pipe when drilling
metal grid,metal plate or the like.
Because the condensed water from rear
of the indoor unit is gathered in ponding
box and is piped out of room. Do not put
anything else in the box.
Fig.4
1. For the left-hand and right-hand piping,
remove the pipe cover from the side panel.
2. For the right back and left back piping,
install the piping as shown.
NOTE:
3. Attach the drain hose to the underside of
the refrigerant pipes with adhesive viny
tape.
4. Wrap the refrigerant pipes and drain hose
together with insulation tape.
5. Open the front panel, then open the wire
cover, connecting the cables.
6. Bundle the pipes, connecting cable, and
drain hose with tape securely, evenly as
shown in Figure on the right.
7. Pass them through the wall hole.
Both sides drainage structure is
standard. For both sides drainage structure,
it can be choosen for right, left or both sides
drainage connection. If choosing both sides
drainage connection, another proper drain
hose is needed as there is only one drain
hose offered by factory. If choosing one side
drainage connection, make sure the drain
hole on the other side is well plugged.
For 9k/12k models, if choosing left-hand
or left-back piping,please choosing left side
drainage connection. The connection of the
drain hose is supposed to be done by
qualified installer in case of water leakage.
Rubber plug
Fig.5
Right rear side
refrigerant pipe
hole 65
Left rear side
refrigerant
pipe hole 65
Indoor unit
outline
219
581
300
53.5
174.3
15.3
47
47
15.3
44.7
53.5
151
148.7
76
1090
338
Mount the Installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The installation plate provided
with the machine differ from appliance
to appliance.
(Dimensions are in mm unless
otherwise stated)
NOTE:
" "
The installation plate is fixed with a screw
for the convenience of shipment, please
remove the screw first before installation.