Installation Instructions

INSTALLTHECONNECTINGPIPE
9
Daubthesurfacesoftheflarepipeandthejointnutswithfrozenoil,andwrenchitfor3~4rounds
withhandsbeforefastentheflarenuts.(Refertochart19)
Besuretousetwowrenchessimultaneouslywhenyouconnectordisconnectthepipes.
CAUTIONS
CAUTIONS
CAUTION
Checkwhethertheheightdropbetweentheindoorunitandoutdoorunit,thelengthofrefrige-
rantpipe,andthenumberofthebendsmeetthefollowingrequirements:
Themaxheightdrop......................................................................................................................20m
(Iftheheightdropismorethan10m,youhadbetterputtheoutdoorunitoverabovetheindoorunit.)
Thelengthofrefrigerantpipe..........................................................................................lessthan30m
Thenumberofbends.........................................................................................................lessthan15
Donotletair,dust,orotherimpuritiesfallinthepipesystemduringthetimeofinstallation.
Theconnectingpipeshouldnotbeinstalleduntiltheindoorandoutdoorunitshavebeenfixedalready.
Keeptheconnectingpipedry,anddonotletmoistureinduringinstallation.
TheProcedureofConnectingPipes
1.Measurethenecessarylengthoftheconnectingpipe,andmakeitbythefollowingway.
(Referto"ConnectThePipes"fordetails)
1)Connecttheindoorunitatfirst,thentheoutdoorunit.
Bendthetubinginproperway.Donotharmtothem.
Chart19 Chart20 Chart21
Usefrozenoil
Bendthepipewiththumb
min-radius100mm
Maketheendstraight
Cutoutadesiredconcaveatthebendingpartoftheinsulatingpipe.
Thenexposethepipe(coveritwithtapesafterbending).
Topreventcollapsingordeforming,pleasebendthepipeatitsbiggestradius.
Usebendertogetasmallradiuspipes.
2)Thestopvalueoftheoutdoorunitshouldbeclosedabsolutely(asoriginalstate).Everytimeyou
connectit,firstloosenthenutsatthepartofstopvalue,thenconnecttheflarepipeimmediately(in
5minutes).Ifthenutshavebeenloosenedforalongtime,dustsandotherimpuritiesmayenterthe
pipesystemandmaycausemalfunctionlater.Sopleaseexpeltheairoutofthepipewithrefrigerant
(R407C)beforeconnection.
3)Expeltheair(refertothe"ExpelTheAir")afterconnectingtherefrigerantpipewiththeindoorunit.
Thenfastenthenutsattherepair-points.
NoticesForBendablePipe
Thebendingangleshouldnotexceed90.
Bendingpositionispreferablyinthemiddleofthebendablepipe.Thelargerthebendingradiusthe
betteritis.
Donotbendthepipemorethanthreetimes.
0
Bendtheconnectingpipeofsmallwallthickness (9.53mm)ะค