Installation Instructions

TESTOPERATION
Aprotectionfeaturepreventstheairconditionerfrombeingactivatedforapproximately3minuteswhen
itisrestartedimmediatelyaftershutoff.
1.Thetestoperationmustbecarriedoutaftertheentireinstallationhasbeencompleted.
2.Pleaseconfirmthefollowingpointsbeforethetestoperation:
Theindoorunitandoutdoorunitareinstalledproperly.
Tubingandwiringarecorrectlycompleted.
Therefrigerantpipesystemisleakage-checked.
Thedrainageisunimpeded.
Theheatinginsulationworkswell.
Thegroundwiringisconnectedcorrectly.
Thelengthofthetubingandtheaddedstowcapacityoftherefrigeranthavebeenrecorded.
Thepowervoltagefitstheratedvoltageoftheairconditioner.
Thereisnoobstacleattheoutletandinletoftheoutdoorandindoorunits.
Thegas-sideandliquid-sidestopvaluesarebothopened.
Theairconditionerispre-heatedbyturningonthepower.
3.Accordingtotheuser'srequirement,installtheremotecontrollerframewheretheremotecontroller's
signalcanreachtheindoorunitsmoothly.
4.Testoperation
Settheairconditionerunderthemodeof"COOLING"withtheremotecontroller,andcheckthe
followingpointsperthe"Owner'sManual".Ifthereisanymalfunction,pleaseresolveitasper
chapter"TroublesAndCause"inthe"Owner'sManual".
1)Theindoorunit
a.Whethertheswitchontheremotecontrollerworkswell.
b.Whetherthebuttonsontheremotecontrollerworkswell.
c.Whethertheairflowlouvermovesnormally.
d.Whethertheroomtemperatureisadjustedwell.
e.Whethertheindicatorlightsnormally.
f.Whetherthetemporarybuttonsworkswell.
g.Whetherthedrainageisnormal.
h.Whetherthereisvibrationorabnormalnoiseduringoperation.
I.WhethertheairconditionerheatswellinthecaseoftheHEATING/COOLINGtype.
2)Theoutdoorunit
a.Whetherthereisvibrationorabnormalnoiseduringoperation.
b.Whetherthegeneratedwind,noise,orcondensedofbytheairconditionerhaveinfluencedyour
neighborhood.
c.Whetheranyoftherefrigerantisleaked.
CAUTION