OWNER S MANUAL AIR CONDITIONER INVERTER ONE-TWO/ONE-THREE / ONE-FOUR TYPE Thank you very much for purchasing our air conditioner. Please read this owner's manual carefully before using your air conditioner. and save it in a safe place for future reference.
NOTICE 1. The outline of air conditioner on the manual cover is sketch map. 2. Before you operating your air conditioner, please read precaution first to avoid air conditioner damage or other accident caused by your mishandling. 3. All pictures are only sketches. If there is any difference between pictures in this manual and the actual shape of air conditioner you purchased, the actual shape shall prevail. 4.
Both indoor units can be operated either simultaneously or separately through the utilization of the advanced converter technique and microcomputer control. The flowing volume of refrigerant is adjustable through the electronic expansion valve. High Cooling and Heating capacity is facilitated through the famous-brand frequency converter compressor. Indoor noise is minimized through the optimization of the air flow system design, a four-folded evaporator and a big diameter Cross Flow Fan.
PARTS NAMES AND FUNCTIONS Indoor unit This chart takes wall-mounted type as example. Air inlet Indoor unit 1. Front panel frame 2. Air filter. Antil- formol filter, HEPA filter 3 Front panel 4. Horizontal air flow grille 5. Vertical air flow louver 6. Room temperature sensor 7. Infrared signal receiver 8. Display lamp 9. Remote Controller Air outlet Air inlet Air outlet Air inlet Outdoor unit 10. Drain hose, refrigerant connecting pipe 11. Connective cable 12. Stop valve 13.
PARTS NAMES AND FUNCTIONS 17C above 17 ~43 30C below -7 ~21 C HANDLING THE REMOTE CONTROLLER NOTES: This model has no ventilation, watering, electric heating functions, so if you push the relative buttons on the remote controller, nothing will happen. MANUAL OPERATIONS NORMAL OPERATION This function is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted. 1. Open the panel and lift the panel up to angle which remains fixed.
Lever The starting angle of the horizontal louver should not be too small, or the narrow air outlet will affect cooling or heating. Do not move the vertical louver manually ,or it may malfunction during operation, If the malfunction happens, please stop operating unpluge for several minutes then plug again and restart. Do not operate the air conditioner for long with the airflow direction set downward during the cooling or drying operation.
2 Any other unusual condition is observed Switch may have blown.
Protection for compressor---you can't start compressor within 3minute.
7 Heating capacity(cooling and heating type) 8.Operation mode selection While simultaneously operating both indoor units, the secondary unit can not be operated in a mode conflicting to that of the primary unit. The unit initially started should be considered as the primary unit. In the circumstance that the operable modes are conflicting with each other, the TIMER lamp and DEF lamp located on the display panel of the secondary unit will flash at a rate of 5 times per second.
Wall-mounted type 1.Open the panel and lift the panel up to the angle which remains. Do not lift the panel any further when it stops with a clicking sound .Lift the raise part in the middle of the cleaning filter and pull it out downward. 2.Take the Anti-formol filter and HEPA filter from the cleaning filter. 3.Be sure to use vacuum cleaner not water to clean the dirty HEPA filter. 4.Clean the air cleaning filter with water or vacuum cleaner, then dry it in cool place.
Duct and Ceiling Type 1. Open the air-in grill Push the grill switches towards the middle simultaneously as indicated in follow figure sketch. Then pull down the air-in grill. Cautions: The control box cables ,which are originally connected with the main body electrical terminators must be pulled off before doing as indicated above. 2. Take out the air-in grill. 3. Dismantle the air filter 4. Clean the air filter (Vacuum cleaner or pure water may be used to clean the air filter.
. . .. .. HINTS FOR OWNER The creepage protector or air switch with a 1.5 times capacity of max. current of unit should be installed in power circuit. A special power circuit and effective electrical outlet should be provided. There has a grounding plug in your unit. Do not modify it by yourself. Please use stated fuse or breaker as described in¡¶Installation Manual¡· Wire construction must be conducted by specified electrician and ensure all construction abide by electric codes.