Use and Care Manual

NOTE
Before making cutouts, make sure there is
proper clearance within the ceiling, wall or cabinet.
1.
2.
3.
4.
Wood filler strips
(recessed cabinet
bottoms only)
Wall
Cabinet
bottom
3” (76
mm)
3” (76
mm)
Fi
tting material is provided
to secure
verify suitability of the materials in
accordance with the type of wall and cabinet.
Install the 4 -
5 mm x 19 mm mounting screws in pilot
holes. Leave about ¼” (6.4 mm) space between
screw heads and cabinet to slide range hood into place.
¹⁄4”
(6.4 mm)
5.
7.
Lift the range hood up under cabine and determine
final location
y centering beneath cabinet. Mark on
the underside of cabinet the location of the 4 keyhole
mounting slots on the range hood (See slot dimensions
on page 6).
Mark rear mounting scr
ew hole locations.
Set range hood aside on a covered surface.
In
stall framing for hood rea
r support
If drywall is present, using the rear mounting screw
hole locations marked in the previous step cut away
enough drywall to expose 2 vertical studs at the rear
mounting screw holes locations. Install horizontal
s
upport at least 4” X 2 ” between two wall studs at
the rear mounting screw holes location. The horizontal
support must be flush with the room side of the studs.
Use cleats behind both sides of the support to secure
to wall studs. Reinstall drywall and refinish.
IMPORTANT – Framing must be capable of supporting
100 lbs.
8.
Centerline of
Installation
Space
View From
Cleats
.
Mounting
Support
8-1/2” min. opening for ductwork
Rear
Use
NOTE: Make the drill holes on the thin area of the slot.
A
A. Drill pilot hole
6.
for top range hood support.
5/64” drill bit and drill 4 pilot holes as shown
the hood to most types of walls and cabinets.
However, a qualified technician must
2” x4” Min
Disconnect power.
Select a flat surface for assembling the range hood.
Place covering over that surface.
Lift the range hood and set it upside down onto cover ed
surface.
If cabinet has recessed bot tom, add
"two - 2” (51 mm)
wide filler strips. Length and thickness determined by
recess dimensions.
Four flat head wood screws or
machine screws wit h
washers and nuts to attach filler
strips in locations shown.
A
. Keyhole slot
B
(100CFM)
(200CFM)
620.7mm
100mm
VENTING REQUIREMENTS
PREPARE THE LOCATION
8