User's Manual
Table Of Contents
- Description
- Attention
- Features
- Controls, Indicators and Connectors
- _
- Front Panel Controls
- _
- Headphone Socket
- High TX Power
- Low TX Power
- Loud Speaker*
- Repeater Mode Indicator LED
- 6. Alarm Mode Indicator LED
- 7. Transmit Mode Indicator LED
- 8. Busy Mode Indicator LED
- 9. Keypad*
- 10. Volume Control*
- 11. Squelch Control*
- 12. Power ON/OFF Switch
- 13. Power On Indicator LED
- 14. Liquid Crystal Display (LCD) (not used on Single Channel Models)
- Symbol
- _
- Rear Panel Connectors
- Front Panel Controls
- _
- Installation and Programming
- Basic Operation
- Front Panel Operation
- Signaling
- Scanning
- Locking the Keypad
- Changing Tone Signaling Systems
- Displaying the Channel Information
- Display of Received Tone Frequencies.
- Bar Graph Displays
- LCD Display Back Light
- Transmit Power Change
- Calling Party ID Display
- Displaying any Radio's ID Number
- Emergency Caller Display
- Automatic Transmit in Repeater Mode
- TX Test Mode
- Keypad Test Mode
- Frequency Band Test Mode
- Starting Message
- Serial Number Display
- EEROM Data Check Mode
- Hardware Error Detection
- RS232C Communications Error
Base Tech II Base/Repeater Station Operator’s Manual
10
•
Keypad Operation using the [SHIFT] Key
Some of the Base Tech II Base Repeater's features and related functions can be changed by using the [SHIFT]
key. To make these changes, it is necessary to first press the [SHIFT] key followed by the other keys within a
two second timeframe.
The following key sequences are used for the purposes described:
[SHIFT]+[0] Toggles the tone system between 5-Tone signaling and DTMF signaling
[SHIFT]+[1] Switches the LCD back-light to the ON or OFF position
[SHIFT]+[2] Toggles the transmitting power between High power and Low power
[SHIFT]+[3] Invalid Key
[SHIFT]+[4] Toggles between "Single Tone Encoding" mode and "5-Tone" or "DTMF" signaling
mode
[SHIFT]+[5] Invalid Key
[SHIFT]+[6] Enters the KILL mode to allow entry of the KILL password
[SHIFT]+[7] Displays the programmed information for the selected (active) channel in the LCD
display
[SHIFT]+[8] Locks or Unlocks the Base Tech II Base Repeater's Keypad
[SHIFT]+[9] Toggles the Base Tech II Base Repeater between "Normal Channel Scanning"
mode and "Priority Channel Scanning" mode
[SHIFT]+[A] Restores a channel to the Channel Scanning List. (The user must first select the
channel to be restored as the active channel)
[SHIFT]+[B] Invalid Key
[SHIFT]+[C] Indicates to the Base Tech II Base Repeater that you have entered the last number
of a DTMF encoding sequence
[SHIFT]+[D] Invalid Key
[SHIFT]+[
•
] Deletes the active channel from the Channel Scanning List
[SHIFT]+[#] Will attach the "R-Number" data to the active encode number and transmit the
whole sequence
[SHIFT]+[CH] Will start or stop the display of the TX and RX bar graphs in the LCD display
[SHIFT]+[SCN] Will place the Base Tech II Base Repeater in the Program Scan mode or exit from
the Program Scan mode
[SHIFT]+[MON] Invalid Key