Product Specifications

12 Through 72 volts on Classic SLs
Classic SL-150 = 96A on 12V, 94A on 24V and 86A on 48V battery
Classic SL-200 = 79A on 12V, 78A on 24+48V and 65A on 72V battery
Classic SL-250 = 61A on 12V, 62A on 24V, 55A on 48V and 43A on 72V battery
Classic SL-150 = 150V + HyperVOC (battery voltage up to 48V) Example 150V + 48V = 198VOC
Classic SL-200 = 200V + HyperVOC (battery voltage up to 48V)
Classic SL-250 = 250V + HyperVOC (battery voltage up to 48V) (NOTE: See HyperVOC at bottom)
98% (Typical system)
2.8W - 4W
Zero - Internal relay for reverse current
Low Battery voltage disconnect and re-connect of loads fully programmable with 2 Auxiliary outputs to control external load
disconnect /re-connect switches
Standard all models - Extended VOC range for cold climates
Standard all models - resettable, no fuse to blow
Bulk, Absorb, Float as well as Equalization
10-100VDC
Adjustable Voltage and Duration, Manual or Auto
Protected to Max VOC ( Classic MPPT Charger Controllers are fully protected from reverse current on both input and output)
Fully protected ( Classic MPPT Charger Controllers are fully protected from reverse current on both input and output)
Fully protected
Automatic when BTS is installed, Adjustable mV per degree C per 2V cell
2 Auxiliary outputs, Aux1 can be 12V out or dry contact, Aux2 is 12V out or Logic IN
Graphical display
Standard 4 conductor phone cable, no hub needed
RS232 and ModBus openly published protocol
Display (MNGP) can be relocated and a second display can be added
75 C
380 days of daily history, 24 hours of data at 5 minute intervals
Requires 2 pole input and output breakers
Minimum of -40C to 50C - Controller will auto derate as temperature rises above 25C
Indoor type IP30 (The Classic is IP22 Rated to 60529 when used with Classic Drip Shield)
Single 1" conduit (35.05mm) on left and right sides. Two 1" conduit (35.05mm) on bottom. Two 3/4" conduit (27.76mm) on back.
5 Year standard
12 Lbs. (5.45 kgs) - 14.9" x 6" x 4" (378mm x 152mm x 102mm)
19" x 8.5" x 5.7" (482.6mm x 215.9mm x 144.78mm)
MNGP graphical display, 3ft networking cable (NOTE: MNGP standard with all Classic SL models)
Listed by ETL for US & Canada, CE Certied, FCC Class B, IEC62109 pending
Nominal Battery Voltage
Maximum Output Current
PV Open Circuit Voltage VOC
(NOTE: See HyperVOC at bottom)
Power Conversion Eciency
Maximum Stand-By Self-Consumption (12V)
Reverse Current At Night
Low Battery Voltage
Hyper VOC (NOTE: See HyperVOC at bottom)
Ground Fault Protection
Charging Regulation
Battery Voltage Regulation Set Points
Equalization Charging
PV Reverse Polarity
Battery Reverse Polarity
Battery Short Circuit
Battery Temp Compensation
Programmable Auxiliary Control Output
Graphic Display
Networking Cabling
Communications
Remote Display
Terminal Rating
Data Logging
Positive Ground Applications
Operating Temperature
Environmental Rating
Conduit knock Outs
Warranty
Weight & Dimensions
Shipping Dimensions HxWxD
Options
Certications
HyerVOC: A non-operative VOC safety zone over and above the maximum input voltage for cold climates.
Classic SL 150, 200 or 250 MPPT Charge Controllers
CLASSIC SL SPECIFICATIONS
www.midnitesolar.com 360-403-7207 17722 - 67th Ave NE, Arlington, WA 98223