Installation Guide

Classic owner’s manual (continued)
39 | P a g e 1 0 - 0 0 1 - 1 R E V : E
Waste Not Hi
This mode is PWM based and will PWM Aux 2 when the Classic gets within a certain range of the
voltage set points for each charging stage (V High) and stop when it gets to a low set point (V Low).
These set points are user adjustable and will allow the Absorb, Float and EQ timers to continue to run.
You will adjust these set points to negative numbers and the numbers are an offset from the voltage set
point. For example a -0.2 would turn Aux 2 on 2 tenths of a volt below your set points. This mode will
allow you maximum diversion while maintaining your 3 stage charging.
Diversion Lo
This mode is PWM based and is just reverse logic of Diversion Hi. It would be comparable to using the
NC contacts of the relay used in Diversion Hi. It can be used that way with a solid state relay and NC
contacts to do diversion above a set voltage.
Diversion Hi
This mode is PWM based and will PWM Aux 2 at a set point based on battery voltage (V High) and stop
it at another set point based on battery voltage (V Low).
Aux 1 Function
OUTPUT = Relay or 12V/0V Signal jumper selectable, ON/OFF Function. (Dry Contact 1A max)
Aux 1 has the relay so Diversion functions must operate slowly
SOC % LOW Battery State of Charge Active LOW
SOC % HIGH Battery State of Charge Active HIGH
GFP TRIP HIGH Ground Fault sets AUX1 HIGH for 0.1 seconds repeatedly
VENT FAN LOW Aux1 on below setpoint
VENT FAN HIGH Aux1 on above setpoint
FLOAT LOW Aux1 off when in Float
FLOAT HIGH Aux1 on when in Float
CLIPPER CONTROL PWM Control for Clipper
DAY LIGHT Aux1 on at dawn off at dusk
NITE LIGHT Aux1 on at dusk off at dawn
TOGGLE TEST Aux1 cycled 1 sec interval
Pv V ON LOW Aux1 on below Pv in setpoint
Pv V ON HIGH Aux1 on above Pv in setpoint
WASTE NOT LO Divert based on charge state lo
WASTE NOT HI Divert based on charge state hi