Mode This menu lets you turn the charging ability of the controller On / Off as well as lets you select the DC input source.
See page 21 for info on the Mode menu.
Mod Bus a standard protocol used for communications. We have published our protocol to allow users to interface with the
Classic. See www.midnitesolar.com for our Mod Bus protocol.
Pwr Save Allows you to adjust the time the Backlight stays on.
Resting The Classic is not charging the battery due to low light. For certain reasons Resting will appear. Please see page 22.
T-Comp Temperature compensation using a temperature sensor to measure the ambient temperature of the battery bank and
will adjust the voltage set points up or down accordingly to ensure a full battery. There are 3 parameters to set Minimum and
Maximum adjusted voltage as well as volts per degree C per Cell. Typically this is -5 mV but please consult your battery
manufacturer. See page 17 for Temperature compensation info.
Tweaks This menu has all the advanced adjustments for the Classic. For example: Voltage off set adjustments etc.
VBatt Battery voltage, measured at the battery terminals of the Classic.
VOC Open Circuit Voltage, unloaded voltage measurement.
Vpv Input voltage, measured at the input terminals of the Classic.