Mode – This menu lets you turn the charging ability of the controller On / Off as well as lets you select the DC input source.
See page 21 for info on the Mode menu.
Mod Bus – a standard protocol used for communications. We have published our protocol to allow users to interface with the
Classic. See www.midnitesolar.com for our Mod Bus protocol.
Pwr Save – Allows you to adjust the time the Backlight stays on.
Resting – The Classic is not charging the battery due to low light. For certain reasons Resting will appear. Please see page 22.
T-Comp – Temperature compensation using a temperature sensor to measure the ambient temperature of the battery bank and
will adjust the voltage set points up or down accordingly to ensure a full battery. There are 3 parameters to set Minimum and
Maximum adjusted voltage as well as volts per degree C per Cell. Typically this is -5 mV but please consult your battery
manufacturer. See page 17 for Temperature compensation info.
Tweaks – This menu has all the advanced adjustments for the Classic. For example: Voltage off set adjustments etc.
VBatt – Battery voltage, measured at the battery terminals of the Classic.
VOC – Open Circuit Voltage, unloaded voltage measurement.
Vpv – Input voltage, measured at the input terminals of the Classic.