Quick Start Guide

Just the Facts for the Classic (continued)
15 | P a g e 10- 2 0 9 - 1 R E V : D
Aux
AUX 1 This is where you configure the Auxiliary one relay. Default is Manual Off. Please consult the manual for
Aux functions.
AUX 2 This is where you configure the Auxiliary one relay. Default is Manual Off. Please consult the manual for
Aux functions.
Misc
Led-Mode This allows you to select between several modes of operation for the LED’s both in the Classic and
MNGP. The default is “Rick Mode” this gives errors only. For more Led functionality please see the Manual.
MNGP Here you can adjust things like Backlight (Default is 400), Contrast (Default is 690) and Volume (Default is
600). You can also hit Play and it will play a beep to allow you to adjust Audio levels to your liking.
Audio Here you can select between the Modes of speech the Classic will use. (Not active yet)
Comm Here you can set the MNGP Address (Default is 110), USB mode (Default is 00) and the ModBus Port
(Default is 502) These will all be fine the way they are unless you have multiple Classic’s and need to change stuff.
Please see the manual for advanced functions.
Time Here you can set or correct the Time and Date. This needs to be set correctly to assure the logged data is time
stamped correctly. The Classic uses a 24 hour clock not an AM/PM clock.
Pwrsv Allows you to select the length of time the backlight on the MNGP stays on after the last button activity.
Default is “OFF” meaning it will always stay on. There is a short (1 minute) and long (6 minutes) setting as well.
Logs
Life Time Shows the life time Kilo Watt hours since the unit was commissioned there is also a “Time in Float” for
today shown as well.
Daily Logs Allows you to scroll back through the previous 380 days of data. The prior day will be day 1 and it
counts back from there. Not the days are also date stamped if the time and date where set correctly. Please consult
the manual for the data that is viewable here as well as the graphs that are viewable.
Hourly Logs Allows you to view the previous 24 hours in 15 minute increments. Please consult the manual for the
data that is viewable here as well as the graphs that are viewable here.
Tweaks
VBatt Allows you to calibrate the battery voltage shown on the Classics screen to agree with the actual measured
battery voltage. Default is 0 volts of offset and this is adjustable from -2.5 to 2.5 volts of offset. The Number below
is the voltage that will be shown on the Classic screen. NOTE if this value is off more than 1 volt please see the
manual for calibrating the voltage using the potentiometer inside the Classic.
Vpv Allows you to calibrate the input voltage shown on the Classics screen to agree with the actual measured input
voltage. Default is 0 volts of offset and this is adjustable from -5 to 5 volts of offset.