Classic Manual Rev-H

Classic owner’s manual Rev H 2056
34 | P a g e 1 0 - 0 0 1 - 1 R E V : H
Dynamic
This is typically used for PV (solar) input sources and tries to follow, on a slow dynamic basis, the
changing conditions of the input source. This mode has one user adjustment which is a forced sweep
perturb trigger interval for times when the input condition changes do not trigger a dynamic sweep. The
interval is in units of minutes.
U-Set VOC%
This is a fully manual mode based on a percentage of VOC. The Classic will sweep based on the user set
time in minutes and then park at a user set percentage of the VOC the Classic found on that sweep. This
mode is useful for testing or constant voltage sources.
Note: Mode must be manually turned ON after changing the mode. To turn the mode ON highlight the
OFF under ON/OFF and switch it to ON. Press enter to save this change.
Configuring the Classic for Wind Input Source
Wind
If you selected “Wind” you will need to select a power curve from the list of pre-loaded curves or build
your own. To access the list of power curves follow the steps below.
Push the Main Menu button.
Scroll left or right until “Mode” is highlighted and push the Enter button.
Set the status to OFF and then use the right soft key to select “Graph”.
Using the left soft key select “MEM”. Now you can scroll up and down through the menu and select the
curve that was designed for your turbine. Once you find the correct power curve use the right soft key to
select “RECALL”. Now push the Enter button to save this power curve to the Classic’s memory.
There are also 9 memory spaces for you to save a custom power curve. To build custom power curves
select a memory location between 1 and 9 and hit “RECALL”. Use the right and left arrow buttons to
scroll through the 16 steps in the custom curve. On each step you can set the amperage by using the up
and down buttons. When you have the power curve the way you want it, select “MEM”. Use the up and
down buttons to select a location 1 through 9 to save it in and select “SAVE”. Now push the Enter button
to save it to the Classic's memory.
For more information consult the videos found at www.midnitesolar.com
Setting the Date and Time
To set the date and time manually on the Classic follow the steps below.
Push the Main Menu button repeatedly until Charge is highlighted.
Scroll left or right to highlight “MISC” and push the Enter button
Scroll to “Time” and push Enter
Now scroll left or right to highlight the data you want to manually change. Use the up and down buttons to
change the data. When you have all the data changed push the Enter button to save the changes.
The Classic includes a battery (CR1216) in the MNGP portion to keep the time running even when the
power is disconnected. To replace the battery refer to the Installation Manual