User Manual

Classic owner’s manual Rev H 2056
36 | P a g e 1 0 - 0 0 1 - 1 R E V : H
SOC % High
This mode will set AUX1 to +12V according to the LOW % and HIGH % settings. HOLD (LOW) and
DELAY (HIGH) activation TIMES can be set in seconds. SOC %=HIGH=12V SOC %=LOW=0.0V
If the classic is set to do an auto-restart at 23:59 (midnight), the state of the AUX1 will be remembered
so it will return to the last state (+12V or OFF) after it resets and comes alive again.
GFP Trip High
This mode sets AUX1 HIGH (+12V) for 0.1 second when a ground fault is detected.
Vent Fan Low
This mode will turn AUX1OFF above the voltage set point you program. It allows you to run a vent fan
for a battery bank based on battery voltage. There is a voltage set point that you set and AUX1 will turn
off when the battery reaches that set point. The voltage has to fall 2 tenths of a volt below the set point for
30 seconds before AUX1 will turn back on.
Vent Fan High
This mode will turn Aux 1 on above the voltage set point you program. It allows you to run a vent fan for
a battery bank based on battery voltage. There is a voltage set point that you set and Aux 1 will turn on
when the battery reaches that set point. The voltage has to fall 2 tenths of a volt below the set point for 30
seconds before Aux 1 will turn off.
Float Low
This mode will turn Aux 1 off whenever the Classic is in Float. Aux 1 will stay off until the Classic falls 3
tenths of a volt below the float voltage set point.
Float High
This mode will turn Aux 1 on whenever the Classic is in Float. Aux 1 will stay on until the Classic falls 3
tenths of a volt below the float voltage set point.
Clipper Control
This mode was intended to control the MidNite Clipper. It will send out a PWM signal whenever the
controller is unloading the turbine because the battery is full or close to it. There are no adjustment in this
mode the Classic is preprogrammed with the best parameters to control turbine RPM.
Day Light
This mode will turn Aux 1 on at sunrise and turn it off at sunset based on the PV input voltage.
Nite Light
This mode will turn Aux 1 on at sunset and turn it off at sunrise based on the PV input voltage.
Toggle Test
This mode will cycle Aux 1 for 1 second off and 1 second on repeatedly. This mode is mostly for testing
purposes.