Installation Guide

The KID Solar Charge Controller Instructions
40 | Page
1 0-268-1 REV P7
FUNC: LBD Low OFF/AUTO -
Enable/Disable/Setup Low Battery Disconnect High
• From the Status Menu: Press Menu Back
• Scroll to the Right and select AUX and Press Enter
• Select FUNC:LBD Low
• Press SETUP button to set the AlrmON Voltage. scroll to the right to set AlrmOFF Voltage.
• Press the Save Button.
• Press the Right arrow button to Auto.
• Press the Save Button
StpCharge H:
When enabled and High signal is sampled in the Aux terminal the Unit will Stop Charging until the High
The MISC menu allows adjustment for:
LCD
- Backlight and contrast controls can be adjusted with the up/down arrow buttons.
See page 45
for more information.
Temp
- Temperature of CPU, FET and Battery in degrees C. The temp can be changed from degrees
C to degrees F using the setup button.
LEDS
- Sets behavior of front panel LEDs. See page 46 for more information.
Timer
- Shows approximate time of day.
Password -
Enable/Disable Password.
See page 45 for more information.
The COMM menu is where stacking is set up. Your choices are Twin Mode and Sync.
Note:
On earlier units
Twin
Mode was known as
Bully
Mode and
Sync
Mode was known as
Follow Me
.
Twin Mode:
is true paralleling where the inputs and outputs are paralleled. You are allowed only two
KIDS in Twin mode. This is a Master/Slave configuration. The Master Twin tells the second KID what to
do.
Sync Mode:
When the master KID changes state, Absorb, Time, Float or Equalize it sends a signal
downstream to the next one to follow and change state. Then the second one sends the same
message downstream and so on until all units are in the new state. There is no limit to how many
controllers can be connected in Sync mode. Both Sync and Twin mode are MidNite Solar exclusive
methods of applying multiple controllers.
Press the right arrow key to advance to the
COMM
menu.
Press the right arrow key to advance to the
MISC
menu.
See page 45 for more information.
signal is sampled Low.
StpCharge L:
When enabled and Low signal is sampled in the Aux terminal the Unit will Stop Charging until the Low
signal is sampled High
OTHER STUFF
AUX < MI SC> COMM
MUL TI PL E UNI TS
MI SC < COMM> TECH