MidNite Solar Kid Manual

The KID Solar Charge Controller Instructions
LED MODE:
Located under the MISC menu, the LED mode can be set to several different modes,
some useful and some just for fun.
NRML: this mode will employ all the available LEDs as indicators, The top 3 LEDs refer to the
Battery Capacity Meter function on The KID that indicates to the user the current battery status
at a glance . The FLT LED will come on when the unit goes to Float. It will blink Slowly when
the unit goes to Float MPPT. This mode will also use the Warning (OVR) LED to indicate when
there is an anomaly on the unit, such as Over Voltage or Current Limit. The ERR LED is also
active to indicate Faults on the system. The CLP LED will come on when the Load is active
and it will blink to indicate a warning on the load circuit.
BCM: The BCM function on the LEDs will only employ the top 3 BCM LEDs and the OVR
and ERR LEDs.
RICK: this mode is also known as minimal LED usage, since it will only use the Warning
and Error LEDs.
PLAY: this mode is great for special occasions where you want to Show off your KID’s fun
side, it will trail the LEDs from top to bottom as long as this mode is selected.
TEST: Useful to verify that all the LEDs are functioning.
OFF: will keep the LEDs OFF, except for the ERROR LED.
Absolute Maximum Ratings
Max Input Voltage PV------------------------------------------------------------- 1 51 -1 62 VDC Non-Operating
Max Operating input Voltage PV----------------------------------------------- 1 50 VDC
Max Input Current PV------------------------------------------------------------- 30 Amps DC
Max Output Current--------------------------------------------------------------- 30 Amps @ 25°C*
Max Input Short Circuit Current------------------------------------------------ 30 Amps DC
Max Output source Backfeed--------------------------------------------------- 30 Amps DC
DC Output Voltage-----------------------------------------------------------------1 2-64 VDC
Input Battery Voltage-------------------------------------------------------------- 1 2, 24, 36, or 48 VDC
Input Battery Voltage Range---------------------------------------------------- 9-64 VDC
Operating Temperature Range------------------------------------------------- -40°C° to 50°C**
*Derated to 20 Amps @ 40°C.
**MNKID-C1 D2 Temperature Range -40°C° to 40°C
Fuses / Overcurrent protection.
Replace fuses with the same type and ratings: Type ATC 32V 30 Amps Max.
The fuses provided in The KID are for supplemental protection. External overcurrent
protection is required as part of the installation.
46 | Page 1 0-268-1 REV T