Installation Guide

The KID Solar Charge Controller Instructions
22 | Page
1 0-268-1 REV P7
Stacking Jumpers
Master Stacking Port
Slave Stacking Port
Jumper settings for stacking (Twin Mode):
In the upper right corner of the circuit board there are two positions for placing jumpers. If not stacking
(only one KID) or stacking two KIDs leave the jumpers off. The jumpers may be placed on one pin to be
saved for later use. When stacking 3 or more KIDs in SYNC mode jumpers should be placed in both
positions on the second and subsequent KIDs. The jumpers should be oriented side to side
(horizontally).
Stacking Ports:
Connect a standard four conductor phone cable (Sold separately) between the
MASTER
jacks of the
first two KIDs.
If additional KIDs are to be connected, connect a standard four conductor phone cable (sold
Separately) from the
SLAVE
Jack on the second KID to the
Master
Jack the next KID.
Continue in the same manner,
Slave
jack of one KID to the Master Jack of the Next KID in line. Up to
1 2 KIDs may be connected in this manner.
USB Connector do not use in hazardous
environment
Serial communications from the stack port:
You cannot have a stacked pair of KIDS and serial data at the same time.
Firmware can be downloaded to upgrade The KID features at
http://www.midnitesolar.com/firmwareIndex.php.
Important!
Do Not make or break connections unless in a non-hazardous area.