KID Manual Firmware 1797 REV D

The Kid Solar Charge Controller Instructions
29 | Page
1 0-268-1 REV D
Scrolling to the right will bring you to the
LOAD
menu.
This is the LOAD Main Menu. It allows numerous types of load functions.
Load Menu:
All loads to be controlled by The Kid are connected to the LOAD terminals of the main KID terminal
block. Note that this output is not intended to control an inverter or other large load. If it is necessary to
control a larger load then use the Kid to control a relay. The relay will then switch the load.
Programming the Load Functions determine how and where the load is connected.
The first screen is Manual on/off. Use the up/down arrow keys to select other modes
SET LOAD/CLIPPER
BATT<LOAD>INPUT
Func: Manual
*Off On
Load Current Limit:
The current limit on the load can be set by the user. Whenever the user current limit is reached the
load will turn off for about 1 0 seconds, it will then try again. If the Max allowable current (30 amperes)
is exceeded, the Load will be turned off and kept off for 3 minutes. It will retry, if the overload condition
is still present, it will stay off for another 3 minutes. The Kid will continue to cycle until the overload
condition is removed. In the Load Status screen it will Say
Over Current!
and the blue LED will blink.
To adjust the Load Current limit:
Press
Main Menu
, select
Battery
and Press
Enter
.
Select
AmpLmt
and press
Enter
.
Select
Load
and use the
Up
and
down
buttons to adjust the limits.
Press
SAVE
Button to save the adjustment.