KID Manual Firmware 1797 REV D

The Kid Solar Charge Controller Instructions
40 | Page
1 0-268-1 REV D
Auto Gen Start (AGS)
This function will try to start the Generator and while monitoring battery
voltage to assure the generator is charging. If not, it will signal the generator to shut down to
conserve fuel.
Generator On at:
Battery voltage level that will trigger the signal to start the generator.
GenStart Delay:
Delay in minutes that the battery voltage must be below the
Generator On at setting ,To signal the generator to start.
MIN Gen Run Time:
Minimum time in minutes the generator will run after Auto Gen Start.
MAX Gen Run Time:
Maximum time in minutes the generator will run after Auto Gen Start.
Gen Run Confirm:
When battery voltage and time requirements for Auto Gen Start have been
met, the Input mode will be turned off for a Qualifying timeperiod.
During this time the kid will look at the battery voltage to see if it has
reached the Gen Run Confirm voltage. If successful the gen run signal will
be kept on for at least the minimum run time. If this voltage is not reached
then the run signal to the Generator will be turned off and a warning LED
will be turned on. In either case the Input mode will be turned back on
after the qualifying time period.