Figure 1.7 shows a more economical method to connect the SPD to the
service entrance distribution panel. This installation utilizes a 240V breaker
that is already in use. This could be a deep well pump, air conditioner etc.
Unless the circuit breaker is listed to have two wires connected, you must
pigtail the wiring as shown. Breakers that are listed for two wires are very
rare, so this method of installing the SPD is probably your best bet.
Some homes have surface mounted distribution panels. Those are
easy to add an SPD to. Simply pop out a 7/8” diameter knockout
and mount the SPD on the hole.
Other homes have service entrances that are flush mounted and
are not exposed. This type of installation will benefit from the
MidNite SPD Flush mount box. Cut a hole in the sheet rock close to
the distribution panel and mount the box in the hole. Secure the
box after wiring is completed using drywall anchors. Make sure to
grommet the hole in the distribution box.
*MIDNITE SOLAR INC. LIMITED WARRANTY. MidNite Solar Surge Protection Device (SPD)
Midnite Solar Inc. warrants to the original customer that the SPD products shall be free from defects in materials and workmanship for a period of
five (5) years. At its option, MidNite Solar will repair or replace at no charge any SPD that proves to be defective within such warranty period. This
warranty shall not apply if the MidNite Solar product has been damaged by unreasonable use, accident, negligence, service or modification by
anyone other than MidNite Solar, or by any other causes unrelated to materials and workmanship. The original consumer purchaser must retain
original purchase receipt for proof of purchase as a condition precedent to warranty coverage. To receive in-warranty service, the defective
product must be received no later than two (2) weeks after the end of the warranty period. The product must be accompanied by proof of
purchase and Return Authorization (RA) number issued by MidNite Solar. For an RMA number contact MidNite Solar Inc, 17722 67th Ave NE,
Arlington, WA 98223(360) 403-7207. Purchasers must prepay all shipping charges to MidNite Solar product under this warranty policy. Except for
the warranty that the products are made in accordance with the specifications therefore supplied or agreed to by customer, MIDNITE SOLAR
MAKES NO WARRANTY IF SPD MCOV RATING IS CHOSEN BELOW SYSTEM’S NOMINAL VOLTAGE. Products will be considered accepted by
customer unless written notice to the contrary is given to MIDNITE SOLAR within ten (10) days of such delivery to customer. MIDNITE SOLAR shall
not in any case be liable for any event occurring or defect discovered with regard to said product unless written notice thereof is given to MIDNITE
SOLAR within ninety (90) days of such product delivery to customer. MIDNITE SOLAR is not responsible for loss or damage to other products
owned by customer and beyond MIDNITE SOLAR’s control. This warranty is in lieu of all other warranties expressed or implied.
MIDNITE SOLAR INC. 17722 67TH AVE NE ARLINGTON, WA 98223
Email: info@midnitesolar.com PH: 360-403-7207 FAX: 360-691-6862
Fig 1.7