Operation Manual

Programmable functions
No. Programmable function Standard Programmable option
P 1 Buzzer volume
1
0 = quiet 1 = loud
P 2 Buzzer at the end of the programme
1
0=Off 1=On
P 3 Memory function
1
0=Off 1=On
P 4 Acoustic tone which sounds when a button is pressed
0
0=Off 1=On
P 5* Water conductivity setting
0
0 = Normal 1 = Low
P 6 Fan and heating during pauses
1
0=Off 1=On
P 7 Cottons and Timed progs. cold/hot reversing on (0 to 99 secs)
87
0 = 0 sec 99 = 99 secs
P 8 Cottons and Timed progs. cold/hot reversing off (3 to 99 secs)
3
3 = 3 secs 99 = 99 secs
P 9 Minimum iron reversing on (0 to 99 secs)
87
0 = 0 secs 99 = 99 secs
P 10 Minimum iron reversing off (3 to 99 secs)
3
3 = 3 secs 99 = 99 secs
P 11 Woollens duration (1 to 99 mins)
5
1 = 1 min 99 = 99 mins
P 12 Woollens programme reversing on (0 to 99 secs)
20
0 = 0 secs 99 = 99 secs
P 13 Woollens reversing off (3 to 99 secs)
10
3 = 3 secs 99 = 99 secs
P 14 Delicates reversing on (0 to 99 secs)
27
0 = 0 secs 99 = 99 secs
P 15 Delicates reversing off (3 to 99 secs)
3
3 = 3 secs 99 = 99 secs
P 16 Timed drying cold (1 to 99 mins)
15
1 = 1 min 99 = 99 mins
P 17 Timed drying warm (1 to 99 mins)
20
1 = 1 min 99 = 99 mins
P 19* Residual moisture for Programme 1
1
1=-2% 2=-4% 0=0%
P 20* Residual moisture for Programme 2
1
1=0% 2=-2% 0=2%
P 21* Residual moisture for Programme 3
1
1 = 20% 2 = 18% 0 = 22%
P 22* Residual moisture for Programme 4
1
1 = 25% 2 = 23% 0 = 27%
P 23* Residual moisture for Programme 5
1
1 = 40% 2 = 38% 0 = 42%
P 24* Residual moisture for Programme 9
1
1 = 20% 2 = 18% 0 = 22%
P 25* Residual moisture for Programme 10
1
1 = 20% 2 = 18% 0 = 22%
P 26* Residual moisture for Programme 11
1
1=10% 2=8% 0=12%
P 27* Residual moisture for Programme 12
1
1=0% 2=-2% 0=2%
P 45 Temperature stages for COP version
(The setting will be available after the machine is con
-
nected to the electricity supply. Can be altered via the tem
-
perature selection button).
2
0 = Cold, 1 = Low, 2 = Medium,
3 = High
* (only for PT 8XX3 machines with Profitronic B Plus Controls)
Reprogramming
17