Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Installation
- Location
- Installation notes
- Building-in dimensions
- Dimensions of the furniture front
- Installing the wine conditioning unit
- Before starting ...
- Tools required
- Weight of the furniture front
- Aligning the building-in niche
- Checking the building-in niche
- Before installation
- Preparing the building-in niche
- Pushing the wine conditioning unit into the building-in niche
- Aligning the wine conditioning unit
- Securing the wine conditioning unit in the building-in niche
- Preparing to install the furniture fronts
- Securing and aligning the furniture front
- Mounting the fixing brackets
- Securing the covers
- Installing the cover in a side-by-side combination
- Fitting the door trim
- Securing the plinth ventilation grille and plinth panel
- Limiting the opening angle of the appliance door
- Electrical connection
- Saving energy
- Guide to the appliance
- Accessories
- Initial commissioning
- Switching on and off
- Selecting additional settings
- The ideal temperature and humidity
- Door alarm
- Storing wine bottles
- SommelierSet
- Automatic defrosting
- Cleaning and care
- Problem solving guide
- Noises
- Service
- EU Conformity declaration
- UK Conformity declaration
- Copyrights and Licences
Installation
*INSTALLATION*
34
Place a spirit level across the installa-
tion aids on the appliance door to
check the wine conditioning unit's
alignment.
Unscrew the adjustable feet
and on both sides at least until the
marking on the plinth has reached the
specified distance of 32mm on the
spacer. The standard dimension of
32mm relates to a niche height of
2134mm.
It is important to adjust the feet to a
height of at least 32mm so that the
ventilation of the wine conditioning
unit via the plinth functions correctly.
Risk of damage if the feet are
adjusted too much.
The rear adjustable feet can be dam-
aged.
Unscrew the feet only until the
marking on the plinth is aligned to a
maximum of 62mm (max. niche
height of 2164mm).
Check the alignment of the wine con-
ditioning unit again using the installa-
tion aids and the spirit level.
Securing the wine conditioning unit
in the building-in niche
Screw the lugs for the fixing plate
into the cabinets/units above the ap-
pliance.