Specs

Pre-finished
18” MasterCool
Please note the following:
• This specication sheet is for a single built-in unit.
• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specication sheet.
*If design calls for a partition less than 6
5
/16” (160 mm) the left unit’s cutout will require an additional
1
/8” (3 mm) to the width to allow installation of
the Heating Mat/Merge Kit.
SPECIFICATIONS
Overall Unit Dimensions 17
3
/4” (451 mm) W x 83
3
/4”- 85
3
/16” (2127 - 2164 mm) H x 24” (610 mm) D [Excludes Fascia Dimension]
Overall Fascia Dimensions 18
1
/2” (470 mm) W x 84”- 85
11
/16” (2134 - 2175 mm) H x 1
1
/2” (32 mm) D
Niche
Minimum Cabinet Niche Opening 18” (458 mm) W* x 84” - 85
3
/16” (2134 - 2164 mm) H x 24” (610 mm) D
Electrical
F 24x1 SF
Electrical Requirements
110V / 120V, 60Hz, 15 Amps
In the case of side-by-side installations, a separate outlet must be used for each appliance.
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing F 24x1 SF
Water Supply Requirements
Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be
connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pressure
must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure
reducing valve must be installed.
Water Connection Line
Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10
mm). Water line is not included.
Shipping
F 2411 SF F 2471 SF
Shipping Weight 357 lbs (162 kg) 378 lbs (171.5 kg)
Shipping Dimensions 21
1
/16” (535 mm) W x 84
1
/4” (1,240 mm) H x 29
7
/8” (759 mm) D
Support
Call Miele (800) 999-1360
Miele Website
8www.mieleusa.com
20/20 Link
82020technologies.com
F 2411 SF (Left Hinged)
Item 37241111USA
Page 2 of 5
F 2471 SF (Left Hinged)
Item 37247111USA