Cutout Specs

Product and Cut-out Dimensions Page 1 of 4
CS 1028 Wok Burner CombiSet
CS
1028
Wok
Burner
CombiSet
Location Codes
Location
Codes
1 – Spring clips
2 – Appliance front
3 – Installation height
4 – Power supply box with connection cable with plug, Length = 47 1/4" (1200 mm)
120 V 60 Hz 15 A fuse rating Actual power consumption (during ignition only) is 25 W
120
V
,
60
Hz
,
15
A
fuse
rating
.
Actual
power
consumption
(during
ignition
only)
is
25
W
.
Ensure that the power outlet is accessible after installation
5 – ½” NPT Gas fitting. The combiset should be ordered for either natural gas or LP gas. For your convenience an AGA
or CGA approved flexible stainless steel gas hose (accordion type) may be used between the gas connection and
the Miele regulator.
6
Rating label
Ensure that the electrical supply matches the rating Adhere rating label sticker supplied with the
6
Rating
label
Ensure
that
the
electrical
supply
matches
the
rating
.
Adhere
rating
label
sticker
supplied
with
the
appliance into the manual.
Shipping weight 28 lbs (12.7 kg)
Shipping dimensions 24” (610 mm) L x 18” (457 mm) W x 10” (254 mm) H
Notes
Indoor use
Deep fat fryers must not be installed directly next to a gas combiset. A minimum distance of 11 5/16” is required.
The appliance must not be permanently sealed into the countertop when installed. The sealing strip under the edge of
the appliance provides a sufficient seal for the countertop.
All installations must be done in accordance with local codes.
Drawing is not to scale Specification Sheets OJS