Operating and Installation Instructions Ventilation System DA 3460 DA 3480 DA 3490 To prevent accidents and appliance damage, read these instructions before installation or use. en - US, CA M.-Nr.
Contents IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Guide to the Ventilation System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Cleaning and care . . . . . . . . . . . . . . . . . . . .
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Keep these instructions in a safe place and pass them on to any future user. Read these instructions carefully before installing or using the Ventilation System. ~ This appliance is intended for residential use only. Use the appliance only for its intended purpose. ~ This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage.
IMPORTANT SAFETY INSTRUCTIONS ~ d) Before connecting the appliance to the power supply make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent appliance damage. If in doubt consult a qualified electrician. ~ e) Installation work and repairs should only be performed by a qualified technician in accordance with all applicable codes and standards. Repairs and other work by unqualified persons could be dangerous.
IMPORTANT SAFETY INSTRUCTIONS ,WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: ~ Do not allow children to play with or ~ a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. ~ Never operate gas burners without ~ b) NEVER PICK UP A FLAMING PAN - You may be burned.
IMPORTANT SAFETY INSTRUCTIONS Installation ~ g) Do not install this hood over cooktops that burn solid fuel. ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ~ a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Functional description The ventilation hood offers two modes of operation: Air extraction Recirculation mode The air is drawn in and cleaned by the grease filters and directed outside. Air is drawn through the grease filters and an active charcoal filter. The filtered air is then recirculated back into the kitchen. The hood comes equipped with a non-return flap. The flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur.
Guide to the Ventilation System 8
Guide to the Ventilation System a Vent connection h On/Off button b Control panel i Power level buttons c Grease filter Four fan speed selection d Expandable fume deflector j Light button e Overhead cooktop light f Active charcoal filter Optional accessory for recirculation mode g Facia Panel Accepts a custom front panel with the DML 400 kit, optional accessory 9
Operation The ventilation system is operated by pulling out and pushing in the expandable fume deflector. To turn the fan on ^ Pull the fume deflector out. To turn the fan off ^ Push the fume deflector back in. The next time the fume deflector is pulled out, the ventilation system will operate at power level 2 again. or The fan turns on to Level 2 . The K symbol and the 2 of the power level indicator light up. All the indicator lights go out.
Operation Automatically switching back the intensive power level The intensive level can be programmed to automatically switch back to level 3 after 10 minutes. ^ To set this option, the fan and the overhead lighting must be turned off and the fume deflector pushed in. Automatic Safety Shut-Off If the ventilation system is left on, the fan will turn automatically off 10 hours after the last button was activated. The lighting however will remain on. ^ Press the On/Off button K to turn the fan back on again.
Cleaning and care ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". Avoid: – cleaning agents containing soda, acids or chlorides, – abrasive cleaning agents e.g. powder or cream cleansers, – abrasive sponges, e.g. pot scourers or sponges which have been previously used with abrasive cleaning agents. These will damage the surface.
Cleaning and care Grease filter Cleaning the filter The reusable metal grease filter removes solid particles from the vented kitchen air (grease, dust, etc). ^ By hand: use a scrub brush with a solution of warm water and mild detergent. Do not use the pure detergent, aggressive all purpose cleaners, oven sprays, abrasive cleaning agents or limescale removers. They could destroy the filter. The grease filter should be cleaned every 3 - 4 weeks. ,A dirty filter is a fire hazard.
Cleaning and care Inserting / replacing the active charcoal filters For recirculation mode an active charcoal filter must be used in addition to the grease filter. The charcoal filter is designed to absorb cooking odors. The active charcoal filter is inserted above the grease filter. ^ To insert the grease filter, make sure that the red plastic guides are at the front and facing up. ^ Insert the grease filter in the deflector and push upwards. It should glide onto the fixing pins.
Cleaning and care Changing the light bulbs ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions". When in use halogen bulbs become extremely hot, use caution. Do not attempt to change the bulbs until they have had sufficient time to cool. Do not touch the bulb surface. Fingerprints or body oils deposited on the bulb will decrease its life.
After Sales Service Repairs MieleCare In the event of a fault which you cannot easily fix yourself, please contact the Miele Technical Service Department. (USA only) ^ When contacting the Technical Service Department, please quote the model and serial number of your appliance. These are shown on the data plate which is visible when the grease filters are removed.
Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most current product specification, technical & warranty information.
Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. Old appliances may contain materials that can be recycled. Please contact your local recycling center about the possibility of recycling these materials. ,DANGER Ensure that any plastic wrappings, bags, etc.
Appliance dimensions 20
Appliance dimensions * The hood can also be installed in a 23 5/8" (60 cm) cabinet.
Appliance dimensions * The hood can also be installed in a 23 5/8" (60 cm) cabinet.
Appliance dimensions 1) Air extraction mode; consider accessories when measuring cabinet height and cut-outs (e.g. muffler). 2) Recirculation mode with Installation kit DUU 151 Distance between cooktop and hood (S) Do not install this exhaust hood over cooktops burning solid fuel.
Installation Installation accessories 24
Installation a 2 runners (1 x right, 1x left) to support the hood in the cabinet. b 1 spacer strip to conceal the gap between the rear of the appliance and the wall.
Installation 26
Installation 1. Installing the space bar T = K cabinet depth minus G hood depth ^ The hood depth G depends on the custom panel: – a Hood installed without front panel – b Hood installed with a cabinet matching custom panel These measures are only valid for the installation if the front panel sits flush with the cabinet corpus (without the door). ^ Screw the space bar flush with the wall under the cabinet side walls.
Installation 2. Runners 3. Installing the hood in the cabinet ^ Lay the hood on its back side. Do not remove the installation protector between the deflector and casing before the installation is completed. The runners are made for side walls of 5/8" (16 mm) and 3/4" (19 mm). Screw on the angled side which has the imprint of the respective cabinet wall measure. ^ Align the runners with the drawn line and be sure that they are flush with the lower edge of the cabinet side wall.
Installation ^ Take the grease filter out and put it aside. ^ Push the deflector back in. ^ Insert the hood into the cabinet from below and until the spring clips click into place. ^ When installing a 29 13/16" (80 cm) or a 35 1/4" (90 cm) hood into a 23 5/8" (60 cm) cabinet, unscrew the deflector spring clips while the deflector is pulled out. ^ To dismount the appliance: unscrew the screws to the left and the right of the inner side of the hood.
Installation 4. Secure the appliance ^ Push the hood back so it sits flush with the front of the spacer strip. ^ Pull the deflector out. ^ Drill respective holes and screw the fixing brackets to the wall or the cabinet rear wall. ^ Screw the hood, with 4 screws, onto the runners. ^ Remove the installation protection between the deflector and casing. ^ Align the casing and tighten the screws. ^ Loosen the screws of the fixing brackets on the hood top.
Installation Weight of the front panel The weight of the front panel must not exceed 2.8 lbs (1.3 kg). This applies for front panels with a depth of up to 1 1/4" (30 mm). In the case of front panels of greater depth or greater weight, the weight must be reduced by milling out the back of the panel, for instance. ^ Connect the space bar from the rear with 4 plastic rivets at the hood rear side. 5. Install the front panel if necessary The installation kit DML 400 is necessary.
Installation 6. Install the grease filter 7. Venting Air extraction mode ^ Complete the venting installation, see "Air extraction". Recirculation mode ^ Remove the protective film from the grease filter frame. ^ To reinsert the grease filter, pull the deflector out. If the hood cannot be installed for air extraction the appliance must be connected for recirculation mode. For recirculation mode a respective installation kit is recommended which can be obtained from Miele.
Installation 8. Electrical connection Refer to the notes in "Electrical connection" and "Important Safety Instructions" before connecting to the mains. ^ Plug in the power cord. ^ Install the installation kit as described in the manual supplied with the kit. ^ Make sure that the slats in the grill point towards the center of the room and not towards a wall or the ceiling. ^ Install the Active Charcoal Filter (see "Cleaning and care").
Air extraction ,WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork.
Air extraction Condensate trap optional accessory – If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. In some cases, a condensate trap may also be required to collect and evaporate any condensate which may occur. This optional accessory is available for ducts 5" (125 mm) and 6" (150 mm) in diameter. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork.
Electrical connection ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed.
Technical data Maximum load . . . . . . . . . . . . . . . 450 W Light. . . . . . . . . . . . . . . . . . . . . 2 x 50 W Voltage . . . . . . . . . . . . . . . . . . . . . 120 V Frequency . . . . . . . . . . . . . . . . . . 60 Hz Circuit rating. . . . . . . . . . . . . . . . . . 15 A Weight DA 3460 . . . . . . . . . . . 27.6 lb (12.5 kg) DA 3480 . . . . . . . . . . . 29.8 lb (13.5 kg) DA 3490 . . . . . . . . . . . . . 32 lb (14.
Alteration rights reserved / 1612 M.-Nr. 09 190 990 / 01 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.