Building Instructions

Technical Information
94
CVA610 Coffee System
6.4 Uneven Filling - When two cups of coffee/espresso
are being prepared at the same time
1. Ensure the appliance is level – correct as necessary.
2. Clean the coffee nozzle.
6.5 Brew Unit – Can’t be removed from appliance
The brew unit is not in the starting (home) position.
Reset the brew unit to the starting (home) position via the
service mode.
The brew unit is jammed and cannot be removed by resetting the
appliance (i.e. shutting the door and turning on the power).
1. Perform the manual removal procedure.
2. Inspect the brew unit and/or drives to locate fault.
6.6 Brew Unit – Can’t be installed
Ensure the handle section marked “PRESS” is pressed during
installation of the Brew Unit. This area is only pressed during
removal of the Brew Unit.
The brew unit is not in the starting (home position).
Perform the “Brew Unit — manual resetting procedure (5.29).
The Drive Shaft is not in the starting (home) position.
1. Reset the brew unit to the starting (home) position via the
service mode.
2. Inspect the Brew Unit and/or drives to locate fault (i.e. defective
switch etc...)