Installation Instruction
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Caring for the environment
- How to save energy
- Guide to the appliance
- Accessories
- Before first use
- Switching on and off
- The correct temperature
- Using Automatic SuperCool and SuperFreeze
- Temperature and door alarm
- Selecting additional settings
- Storing food in the refrigerator section
- Adjusting the interior fittings (refrigerator section)
- Freezing and storing food
- Making ice cubes
- Defrosting
- Cleaning and care
- Frequently Asked Questions
- Causes of noises
- Technical Service
- Water connection
- Electrical connection
- Installation
- Changing the door hinges
- Removing the door handles
- Removing the upper soft-close mechanism
- Removing the upper appliance door
- Removing the lower soft-close mechanism
- Removing the lower appliance door
- Refitting the lower appliance door
- Inserting the lower soft-close mechanism
- Refitting the upper appliance door
- Inserting the upper soft-close mechanism
- Refitting the handle
- Aligning the machine doors
Frequently Asked Questions
55
Problem Possible cause and solution
After a while, the temperature will return to normal by
itself.
If a thick layer of ice has already formed, this will af-
fect cooling and increase energy consumption.
Defrost the machine and clean it.
The ambient temperature is too high. The higher the
ambient temperature, the longer the compressor has
to run.
See the information in the section on “Installation –
Installation location”.
The temperature setting is too low.
Correct the temperature setting.
A large amount of food was put in for freezing at
once.
See the information in the section on “Freezing
and storing food”.
The Automatic SuperCool function is still turned on.
To save energy, you can turn Automatic SuperCool
off early yourself.
The SuperFrost function is still turned on.
To save energy, you can turn SuperFrost off early
yourself.
The compressor comes
on less and less often
and for shorter periods
of time. The tempera-
ture in the appliance
rises.
This is not a fault. The temperature setting is too high.
Correct the temperature setting.
Check the temperature again after 24hours.
The food begins to thaw.
The room temperature is too low for this appliance.
If the room temperature is too low, the compressor
will run less frequently. This may cause the freezer to
become too warm.
See the “Installation location” section in the “In-
stallation information”.
Increase the room temperature.
The door seal is dam-
aged or needs to be re-
placed.
No tools are required to change the door seal.
Change the door seal. A replacement is available
from Technical Service.