User manual

Problem solving guide
76
Message Cause and remedy
Drain valve fault
Switch off/on
The residual water drawer has not been detected.
Press the button to switch the steam ironing
system off and then back on again.
After switching the steam ironing system off and
back on, the residual water drawer has not been de-
tected.
Press the button to switch the steam ironing
system off.
Clean and dry the metal discs (contacts) on the re-
sidual water drawer.
Use the button to switch the steam ironing sys-
tem back on and follow the instructions shown in
the display:
Remove the residual water drawer and fill it with
fresh tap water.
Put the filled residual water drawer back in the
tower.
Remove the residual water drawer again when you
are prompted to do so and the appropriate mes-
sages are shown in the display.
Empty and dry the residual water drawer.
Put the empty residual water drawer back in the
tower.
The steam ironing system is now ready for operation
and will continue to operate from the point reached
before the fault was registered.
There is a fault with the steam ironing system.
If the fault message continues to be displayed,
contact Miele Service.
Fault codes:
F38: ELP/EW/LNG
F44
F45: LNG
F47
There is an internal fault.
Press the button to switch the steam ironing
system off and then back on again.
The steam ironing system will try and rectify the fault
itself.
If the fault message continues to be displayed, con-
tact Miele Service.