Operating & Installation Instructions
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Guide to the appliance
- Accessories
- Operation
- Before using for the first time
- Filling the water tank
- Filling the coffee bean container
- Turning the machine On and Off
- Dispenser adjustment
- Preparing beverages
- Coffee the way you like it
- Portion size
- Resetting drinks
- User profiles
- User profiles: Creating and editing your own drinks
- MyMiele
- Settings
- Accessing the "Settings" menu
- Changing and saving settings
- Setting options
- Language
- Time of day
- Date
- Timer
- Eco mode
- Lighting
- Start screen
- Info (displaying information)
- Locking the coffee system (System lock )
- Water hardness
- Display brightness
- Volume
- Activating and deactivating water connection
- Dispenser adjustment
- Factory default setting
- Showroom program (Demo mode)
- Cleaning and care
- Overview
- Clean by hand or in dishwasher
- Drip tray
- Drip tray cover
- Water tank
- Waste unit
- Main dispenser
- Sensor cover
- Maintenance of the milk valve
- Milk flask with lid
- Bean container
- Interior and machine front
- Main dispenser connector
- Brew unit
- Care programs
- Rinsing the coffee system
- Rinsing the milk pipework
- Cleaning the milk pipework
- Degreasing the brew unit
- Descaling the machine
- Frequently Asked Questions
- Technical Service
- Saving energy
- Packaging material / Disposal of old machine
- Plumbing
- Electrical connection
- Installation
- Copyright and licenses
Frequently Asked Questions
89
Exchanging the elbow connec-
tor
If you can prepare only hot milk instead
of milk froth, check the following first:
– Is the milk in the milk flask cold
(<50°F / 10°C)?
– Have the main dispenser and milk
flask lid been cleaned carefully?
– Is the main dispenser correctly
mounted?
If you still cannot prepare milk froth, fol-
low the steps described to exchange
the elbow connector.
You need the elbow connector that was
provided as a spare part.
Do not use a needle or similar imple-
ment. This would damage the com-
ponents.
Open the service cover on the back
of the appliance door.
First release air intake tube from
the opening Then pull off the el-
bow connector .
Pull both tubes out of the elbow con-
nector.
Use the cleaning brush supplied to
clean air intake tube under running
water. "Blowing through" can help to
dislodge blockages.
Insert the brush in milk tube . Move
the brush back and forth as far as
possible until all milk deposits have
been removed.
Now take the new elbow connector