Installation Instructions DA 186, DA 188, DA 189 en-CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions.
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Keep these operating instructions in a safe place and pass them on to any future user. Read these Instructions carefully before installing or using the Ventilation System. ~ This appliance is intended for residential use only. Use the appliance only for its intended purpose. ~ This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage.
IMPORTANT SAFETY INSTRUCTIONS ~ d) Before connecting the appliance to the power supply make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent appliance damage. If in doubt consult a qualified electrician. ~ e) Installation work and repairs should only be performed by a qualified technician in accordance with all applicable codes and standards. Repairs and other work by unqualified persons could be dangerous.
IMPORTANT SAFETY INSTRUCTIONS ,WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING* ~ Do not allow children to play with or ~ a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. ~ Never operate gas burners without operate the appliance or its controls. Supervise its use by the elderly or infirm.
IMPORTANT SAFETY INSTRUCTIONS Installation ~ g) Do not install this hood over cooktops that burn solid fuel. ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ~ a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Appliance dimensions * Cabinet panel dimensions Air extraction connection C 4 3/4" (120 mm).
Appliance dimensions Distance between cooktop and hood Do not install this exhaust hood over cooktops burning solid fuel. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood: Miele Cooktops Non-Miele Cooktops Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26" (660 mm) Multiburner Gas cooktops < 43,000 BTU (12.6 KW) and no burner > 15,000 BTU (4.
Installation Before installation, read the information on "IMPORTANT SAFETY INSTRUCTIONS". Under certain conditions there is a risk of carbon monoxide poisoning, especially if you operate the range hood simultaneously with an open fireplace. ^ Take out the grease filter and remove the protective foil from the filter frame. Installing the cabinet door ^ Open the vapour canopy. ^ Pull the sliding catch forward to release the canopy and swing it forward and upwards.
Installation Adjusting depth To install a plywood backing The whole weight of the installed ventilation system has to be supported by the mounting plates. They must be firmly attached to stud framing behind the drywall. If studs are not available directly behind both mounting plates, a plywood backing (min. 2" (51 mm) thick) spanning at least two studs must be installed.
Installation ^ Make a cutting line 13" (330 mm) below the the top edge marking. Wall attachment ^ Find the studs to the left and right of the appliance location by tapping the wall or using a stud finder. ^ Mark a vertical cutting line along the center of each stud. Be careful not to damage any wiring or plumbing that may be located behind the wall. Make sure that the power supply to the area where this installation is being performed has been turned off at the breaker panel before cutting into the wall.
Installation ^ For Recirculation the reducing collar with the non-return flap must be removed by unscrewing the screws and installing the recirculation grille. ^ Hang the range hood in position using the adjustable brackets. ^ Using a screw driver, pry out one of the covers for feeding through the power cable. ^ Position the vapour canopy with the cabinet front fitted and close it.
Installation The movement of the vapour canopy can be adjusted. This may be necessary, for instance, if a heavy cabinet panel is mounted. In the front of the lower edge of the unit, two openings (right and left) give access to two adjustment screws. ^ Remove both cover caps. ^ Using a Philips screwdriver, adjust both sides evenly: - clockwise: the folding mechanism becomes stiffer. - counterclockwise: the folding mechanism becomes freer.
Installation Securing the appliance to neighbouring wall units or fitting side panels ^ Remove the vapour canopy. ^ For air extraction mode: ^ With grease filters removed, secure the range hood, or fit the side panels, using two screws per side. For the lower screws, first remove the screw caps, and replace them afterwards. ^ Replace the vapour canopy. – Fit flexible ducting or a extraction pipe to the discharge connection, using a hose clamp. – Now fit the other discharge air connection.
Electrical connection All electrical work should be performed by a qualified electrician in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. The manufacturer can not be held responsible for unauthorized work. Ensure that power to the appliance is OFF while installation or repair work is performed.
Air extraction ,WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork.
Air extraction – If the exhaust is ducted through an outside wall, a Miele Telescopic Wall Vent can be used. – If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue. Important If the ductwork runs through rooms, ceilings, garages, etc.
Technical data Total connected load. . . . . . . . . . 260 W Fan motor . . . . . . . . . . . . . . . . . 220 W Cooktop lighting . . . . . . . . . . 2 x 20 W Power supply voltage . . . . . . . . . 120 V Cycles (Hz) . . . . . . . . . . . . . . . . ~ 60 Hz Fuse rating (amps) . . . . . . . . . . . . .
Alteration rights reserved / 2810 M.-Nr.