Operating and installation instructions Cooker hoods DA 3160 DA 3180 DA 3190 DA 3160 EXT DA 3190 EXT To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time. en - GB M.-Nr.
Contents Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warning and Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Guide to the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Description of the functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Operation . . . . . . . . . . . . . . . . . . . . . . .
Caring for the environment Disposal of the packing material Disposal of your old appliance The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and should be recycled. Electrical and electronic appliances often contain materials which, if handled or disposed of incorrectly, could be potentially hazardous to human health and to the environment. They are, however, essential for the correct functioning of your appliance.
Warning and Safety instructions This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time. They contain important information on the safety, installation, use and maintenance of the appliance.
Warning and Safety instructions Technical safety ~ Before installation, check the cooker hood for visible signs of damage. Under no circumstances should you use a damaged appliance. It could be dangerous. ~ Before connecting the appliance to the mains supply, make sure that the voltage and frequency details given on the data plate correspond with the on-site electricity supply, otherwise the appliance could be damaged. Consult a qualified electrician if in any doubt.
Warning and Safety instructions ~ Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). Using at the same time as other heating appliances that depend on the air from the room Warning - danger of toxic fumes ~ For appliances with an external fan motor fitted (...
Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure of 0.04 mbar (4 pa) is the maximum permissible in the room. One of the following technical measures may be necessary to ensure safe operation.
Warning and Safety instructions Correct use ~ Never use an open flame beneath the cooker hood. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the cooker hood could draw flames into the filter. Fat particles drawn into the cooker hood present a fire hazard. ~ When using the cooker hood over a gas hob, ensure that any burners in use are always covered by a pan. Switch the cooking zone off when a pan is removed, even for a short time.
Warning and Safety instructions Correct installation Accessories ~ Refer to the cooker or hob manufacturer's instructions as to whether a cooker hood may be operated above the cooker/hob. ~ Only use genuine Miele spare parts ~ The minimum safety distances between the top of the cooker or hob and the bottom of the cooker hood given in the "Appliance dimensions" section of this booklet must be maintained, unless the hob manufacturer states that a greater safety distance is required.
Guide to the appliance 10
Guide to the appliance a Exhaust socket ø 150 mm b Control panel c Grease filter d Pull-out deflector plate e Hob lighting f Charcoal filter (extra accessory available to order for recirculation mode) g Drop-down lightshield to conceal control panel The front of the deflector plate can be fitted with a lightshield to match your kitchen furniture. The DA 3160 and DA 3190 can be fitted with a DFB 61 or DFB 91 lightshield, available as an optional accessory.
Description of the functions The cooker hood works with . . . air extraction: The air is drawn in, cleaned by the grease filter and then directed outside. If the on-site ventilation system does not have a non-return flap, then the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit. Having a non-return flap fitted in the ducting ensures that air, once ducted to the outside, cannot get back into the room again.
Operation The cooker hood is operated by pulling out and pushing in the deflector plate. To switch the fan on ^ Pull out the deflector plate. The fan will begin to operate at setting II. For short periods of cooking food with intensive vapours and a strong aroma, e.g. when searing meat, you may wish to select the Intensive Setting "IV". Pull the deflector plate right out to achieve optimum extraction and to prevent unnecessary noise levels.
Operation Automatic switch-off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III. ^ To set this option, both the fan and the hob lighting must be switched off and the deflector plate pushed in. ^ Press the – and + touch controls at the same time for approx. 10 seconds until the first power level indicator lamp lights up in the display. ^ Press the + touch control to activate automatic switch-off.
Cleaning and care A range of Miele branded cleaning and conditioning agents are available to order through your Miele Dealer/ Chartered Agent, the Miele Spare Parts Department or via the internet at www.miele-shop.com. ,Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply. ,Halogen lamps get very hot during use and remain hot for some time after being switched off. The hot lamps are also susceptible to damage from damp cleaning.
Cleaning and care Controls The controls may suffer discolouration or damage if soiling is left on them for too long. Remove soiling straight away. Observe the General notes on cleaning earlier in this section. Do not use stainless steel cleaning agents on the controls. Grease filter The re-usable metal grease filter in the appliance removes solid particles from the kitchen vapours (grease, dust, etc) preventing soiling of the cooker hood.
Cleaning and care Cleaning the grease filters by hand ^ Clean the filters with a soft nylon brush in a mild solution of hot water and a small amount of washing-up liquid. Do not use undiluted washing up liquid. ^ When removing the filter for cleaning, also clean off any residues of oil or fat from the now accessible housing to prevent the risk of these catching fire.
Cleaning and care Fitting and replacing the charcoal filter If the cooker hood is connected for recirculation, a charcoal filter (optional accessory) must be inserted in addition to the grease filter. This is designed to absorb cooking smells. It is fitted in the canopy above the grease filter. Replacement charcoal filters can be obtained from your Dealer / Chartered Agent or the Miele Spare Parts department or via the internet on www.miele-shop.com.
Cleaning and care Changing a halogen lamp ^ Pull out the deflector plate, and remove the grease filter as described earlier. ^ Switch off the fan and the lighting. ,Exercise caution when changing halogen lamps. They get very hot during use, and remain hot for some time after being switched off. Do not touch the surface directly when changing a lamp, as grease particles from your fingers will adhere to the surface and damage it. Please follow the manufacturer’s instructions.
Appliance dimensions DA 3160 DA 3190* 1) The front section of the wall housing unit must be fitted with a shelf to the depth of the partition wall. 2) The partition wall in the wall unit must be removable. 3) In extraction mode: when measuring for the height of the wall housing unit and the cut-out, account must be taken of any accessories fitted, e.g. silencer, DSM module. 4) Recirculation mode with conversion kit DUU 151. 5) Accessory DSM 400. * Installation is also possible in a 600 mm wide unit.
Appliance dimensions Safety distance between hob and cooker hood The minimum safety distances between the top of a cooker or hob and the bottom of the cooker hood are as follows, unless a greater distance is specified by the manufacturer of your cooking appliance: – 450 mm above electric hobs and cookers, – 650 mm above an open grill or deep fat fryer, – 650 mm above gas hobs and cookers.
Installation Installation accessories 22
Installation a 1 exhaust connection for exhaust ducting C 150 mm. b 1 reducing collar for exhaust ducting C 125 mm. c 1 non-return valve for fitting into the exhaust connection (not for recirculation mode). 14 screws 3.5 x 16 mm for securing the cooker hood into the wall unit. d 2 brackets to support the appliance in the wall unit. 8 screws M4 x 12 mm for securing the cooker hood to the brackets. e 1 spacer strip to conceal the gap between the rear of the appliance and the wall.
Installation 24
Installation Positioning the appliance in the wall housing unit To position the appliance correctly, cut the spacer strip to required depth T, and then attach it to the back of the appliance. T= Depth of carcase K minus depth of appliance G ^ The depth of appliance G depends on the lightshield being used: ^ Screw the spacer strip to the bottom of the sides of the housing, flush with the rear wall.
Installation ^ Place the appliance on its back. Do not remove the protective film between the deflector plate and the casing until the hood has been placed in the housing unit. ^ Screw the brackets onto the right and left inside walls of the housing unit as shown. The back edge of the brackets should align with the vertical line drawn up from the front of the spacer strip, and the lower edge aligned with the lower edge of the housing unit side wall.
Installation ^ When fitting a DA 3180 or a DA 3190 appliance into a 60 cm unit, unscrew the brackets on the deflector plate whilst it is pulled out. Note for dismantling the cooker hood: Undoing the screws on the left and right inside the housing releases the brackets, allowing the appliance to be removed from the unit. ^ Push the cooker hood back against the spacer strip. ^ Pull out the deflector plate. ^ Secure the appliance to the brackets using two screws on each side.
Installation Attaching the lightshield ^ Secure the front of the appliance to the floor of the housing unit from below using 4 screws (6 screws for 90 cm wide cooker hood). To avoid damaging the deflector plate when it is pulled out, care should be taken to screw the fixing screws in straight, and to ensure that the screwheads are countersunk. ^ Attach the lightshield (if using). A DML 300 installation kit, available as an optional accessory, is required for this.
Installation Aligning the deflector plate Fitting the grease filter ^ Remove the protective strip around the edge of the grease filter. Fit the grease filter. ^ The position of the deflector plate can be brought forward by up to 50 mm using the adjusting screws on either side of the deflector plate. Align the deflector plate to the front of the kitchen furniture units on either side. ^ To do this, pull the deflector plate out.
Installation Setting up for extraction mode ^ If the on-site ventilation system does not have a non-return flap, then the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit. ^ When using C 150 mm ducting, secure the exhaust connection supplied to exhaust ducting with hose clips. ^ If using C 125 mm ducting, fit the reducing collar into the exhaust connection, and secure the exhaust ducting to the reducing collar with a hose clip.
Installation Setting up for recirculation mode If site conditions are not suitable for the cooker hood to be used with air extraction, the appliance must be set up for recirculation. ^ Make sure that the slats in the exhaust grille point towards the centre of the room and not towards a wall or the ceiling. A non-return flap is not used in recirculation mode. ^ Fit the charcoal filter (see “Cleaning and care”).
Connection for air extraction Important: To avoid the danger of toxic fumes, please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations. Seek approval from the building inspector where necessary.
Connection for air extraction – If the exhaust air is to be ducted into the open air, the installation of a telescopic wall vent or roof vent (available as an optional accessory) is recommended. Condensate trap (optional accessory) – If the exhaust air is to be ducted into a vent flue, the ducting must be directed in the flow direction of the flue. Important: If the exhaust ducting is to run through rooms, ceiling space etc.
Connection for air extraction Silencer ...with air extraction: (optional accessory) The silencer not only reduces noise from the fan, but also sounds from outside (e.g. traffic noise). For this reason the silencer must be positioned as close as possible to where the ducting leaves the building a. ...in recirculation mode: The silencer needs to be positioned between the fan and the exhaust grille b. The space needs to be checked in some cases.
Electrical connection All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable. Ensure power is not supplied to the appliance until after installation or repair work has been carried out.
Operation with DSM 400 control module The Miele DSM 400 control module can be used to combine the cooker hood with other components. It enables the following: Connection to a window contact switch If adequate ventilation to the room can only be ensured by having a window open when the cooker hood is in use at the same time as a heating appliance which depends on the air from the same room, then the control module can be used to connect a window contact switch (not supplied) to the appliance.
Operation with DSM 400 control module Connection to a light switch The control module can be used to switch on the cooker hood lighting via a light switch in the house. Installation The control module must be installed above the cooker hood housing. The control module is supplied with its own detailed operating and installation instructions.
After Sales Service In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – Your Miele Dealer / Chartered Agent or – The Miele Service Department (see back cover for address). When contacting your Dealer or Miele, please quote the model and serial number of your appliance. These are shown on the data plate which is visible when the grease filter is removed. For G.B.
Technical data Connected load* . . . . . . . . . . . . . 280 W Fan motor* . . . . . . . . . . . . . . . . . 180 W Hob lighting . . . . . . . . . . . . . . 2 x 50 W * For EXT models the connected load and extraction power will depend on the type of external motor fitted. Voltage . . . . . . . . . . . . . . . . . AC 230 V EXT models: Length of connection cable to external motor. . . . . . . . . . . . . . . . . . . . . . . 1.9 m Frequency . . . . . . . . . . . . . . . . . . 50 Hz Fuse rating (UK) . . . . .
Alteration rights reserved / 1111 M.-Nr.