Operating instructions/Installation instructions
Installation
*INSTALLATION*
39
a
Extraction, recirculation with
conversion kit DUU150.
b
The wall unit carcase needs to be
38mm shorter than the wall unit
door.
c
Installation is also possible in a
600mm wide cabinet. The following
should be noted:
– The adjoining units must also be
shortened by 38mm.
– The doors of the housing unit and
of adjoining units must open
upwards so that the grease filters
are accessible.
d
Alternative ducting connection at the
back.
e
Wall unit can be fitted with partition
wall after installation. Slots for the
grease filters, and with recirculation
mode for the charcoal filters, must
remain accessible.
f
Alternatively the wall unit can be
fitted with side sections.
g
If the wall unit has a base panel,
openings must be provided to adjust
the retaining force of the deflector
plate. Examples:
– The wall unit has side sections, as
shown.
– The cooker hood is installed in a
600mm wide unit with units at
either side.
The height of the wall unit and cut-out
dimensions must take account of any
accessories fitted, e.g. silencer, DSM
module.