Installation recommendations
- To achieve optimum vapor extraction,
the hood must be centered over the
cooktop, not to the side.
- The mounting area must be easily
accessible. The ventilation hood
should be easy to reach and
disassemble in case a service call is
necessary. This should be taken into
consideration when planning the
position of cabinetry, shelves,
ceilings or decorative elements in the
vicinity of the ventilation hood.
Air venting
WARNING: Danger of toxic fumes.
Gas cooking appliances release
carbon monoxide that can be
harmful or fatal if inhaled.
To reduce the risk of fire and to
properly exhaust air, the exhaust
gases extracted by the hood should
be vented outside of the building
only.
Do not vent exhaust air into spaces
within walls or ceilings or in attics,
crawl spaces or garages.
To reduce the risk of fire, only use
metal ductwork.
Please read and follow the
“IMPORTANT SAFETY
INSTRUCTIONS” to reduce the risk
of personal injury. Follow all local
building codes when installing the
hood.
Only use smooth pipes or flexible
ducting made from approved non-
flammable materials for ducting.
To achieve the most efficient air
throughput with the lowest noise levels,
please note the following:
- The diameter of the vent ducting
must not be smaller than the cross-
section of the vent collar (see
Appliance dimensions”). This applies
in particular when using flat ducting.
- The ducting should be as short and
straight as possible.
- Only use wide radius bends.
- The ducting must not be kinked or
compressed.
- All connections must be strong and
airtight.
- If the ducting has flaps, these must
be opened whenever the ventilation
hood is switched on.
Any constriction of the air throughput
will reduce extraction performance
and increase operating noise.
Ventilation stack
If the exhaust air is to be ducted into a
flue, the ducting must be directed in the
flow direction of the flue.
If the flue is used by several ventilation
units, the cross-section of the flue must
be large enough.